When consumers use air conditioning, air conditioning failure will inevitably encounter problems, which usually occurs when the air conditioning display a code to indicate what kind of problems there are now air-conditioned, but for consumers, these codes really mean What is it? Wide Web home network on the market for you to order a more mainstream fault code eight brands of air conditioning products, can help you understand what kind of air conditioning actually encounter problems, here we come to learn about it! Gree air-conditioning fault code complete E1: Compressor current is too large, the compressor overheating, high exhaust temperature, module protection, you should check whether the disconnection and compressor overload protection, temperature of short circuit. E2: indoor evaporator frost protection. E3: indoor temperature thermal head shorted or open. E4: indoor evaporator tube temperature thermal head shorted or open. E5: indoor and outdoor communication failure. Gree E1 Remedy First, determine the air conditioner is running for some time or boot failure fails to distinguish between a system failure or circuit failure, systems main considerations: 1) emptying dirty / new installations 2) excess punch Note / repaired 3) outside the machine High temperature / poor ventilation? Fouling? Harsh environment? Circuit: the short board within ovc with the zero line, if they continue to fail, then motherboard bad / exchange, repair, if not failure, check whether the high-pressure switch is turned on (the switch should be turned on under normal pressure), such as pass, check high-voltage switchgear and ovc connection, such as unreasonable, repair high-voltage switch. First, determine the air conditioner is running for some time or boot failure fails to distinguish between a system failure or circuit failure, systems main considerations: 1) emptying dirty / new installations 2) excess punch Notes / repaired 3) outside machine High temperature / poor ventilation? Fouling? Harsh environment? Circuit: the short board within ovc with the zero line, if they continue to fail, then motherboard bad / exchange, repair, if not failure, check whether the high-pressure switch is turned on (the switch should be turned on under normal pressure), such as pass, check high-voltage switchgear and ovc connection, such as unreasonable, repair high-voltage switch. Gree fixed-frequency machine fault codes E1 --- Compressor high pressure protection E2 --- Indoor anti-freeze protection E3 --- compressor and low pressure protection E4 --- exhaust pipe temperature protection E5 --- Low-voltage protection E6 --- electrostatic precipitator Gree air-conditioning fault code! KF-60L WAK closet type room air conditioner split fault code: E1 1, there are obstacles in front condenser 2, the control circuit Xun Chang 3, the outdoor ambient temperature higher than 43 degrees start cooling 4, the high-pressure pipe pressure Ambassador high voltage switching operation E2 1, indoor fan does not turn or outlet blocked 2, the indoor ambient temperature is below 18 degrees 3, the tube temperature thermal head fracture 4, the tube temperature thermal head plug not plugged in 5, the control circuit Xun Chang 6, the capacitor C7 leakage LF-12WAK closet type room air conditioner split fault code: E1 1, there are obstacles in front condenser 2, the control circuit Xun Chang 3, three-phase power phase 3, the outdoor ambient temperature higher than 43 degrees start cooling 4, Working current Ambassador had protector action or high-pressure pipe pressure Ambassador high voltage switching operation E2 1, indoor fan does not turn or outlet blocked 2, the indoor ambient temperature is below 18 degrees 3, the tube temperature thermal head fracture 4, the tube temperature thermal head plug not plugged in 5, the control circuit Xun Chang 6, the capacitor C7 leakage Gree air-conditioning maintenance One: Gree fixed frequency machine hook sensor resistance is relatively small, that is more accurate, but also the most likely bad common fault will not say say two bad check in:!! About 20 minutes when a refrigerant pressure machine stop; 2 heating outside the fan does not work; great indoor pipe temperature may have been the problem (for all fixed-frequency machine)! Two: Ordinary split type, 1: is the E1 with boxes of performance for a boot immediately stop, in addition to boxes can start other things functions are not used (Simple Solution: The control panel OVC line with the zero line shorted, E1 to the control panel is still bad, do not show that high-voltage protection E1 disconnect switch, etc.) 2: E3 fault some machines simply do not switch low-voltage protection, but also to change all control elements Not solve the problem, the original is now a lot of the control panel are common, LPP line with the zero line shorted as long as the control panel can be! Three: Frequency calm Wang maintenance information 1 exhaust temperature protection: When the T exhaust higher than 115 degrees, press stop, press stop reached less than 90 degrees for three minutes after the resumption of operation; 2 anti-freeze protection: When the tube T is less than -1 degrees, press stop, press stop has reached more than 6 degrees three minutes to resume operation; 3 over-current protection: When I total is greater than D, press stop, external fan stop delay 30 seconds Cooling 32 machine D = 10A, 25 machine D = 8A; 32 machine heating D = 13A, 25 machine D = 10A 4 Overload protection: When the T-tube is greater than 62 degrees, according to the set wind speed within the fan run, press stop. T tube: outdoor heat exchanger temperature cooling, heating when the indoor heat exchanger temperature. 5 indoor and outdoor fault display: D1, D2, D3 of the machine lamp, LED1 (green) LED2 (Red) LED3 (yellow) for the external machine lights. A press stop and LED1 lights when there is a fault; when the outdoor temperature is faulty B L E1: system (compressor discharge pressure) high pressure high pressure protection; E2: indoor evaporator anti-freeze protection temperature is too low or the tube temperature temperature sensor failure (damage) protection, or a circuit board failure! E3 --- low pressure compressor (compressor suction pressure) is too low to protect E4 --- compressor discharge pipe temperature protection E5 --- Low-voltage protection E6 --- electrostatic precipitator Gree air-conditioning fault code Gree: Frequency Guiji E1-E5 E1: press overcurrent, overheating, excessive exhaust, module protection; E2: indoor anti-freeze protection; E3: indoor temperature thermal package open, short circuit; E4: indoor pipe temperature start, short circuit; E5: indoor and outdoor communication failure. : Fixed-frequency machine fault codes: E1: Compressor high pressure protection E2: Evaporator anti-freeze protection E3: Compressor voltage protection E4: compressor discharge temperature protection E5: over-current (low voltage protection) LF-12WAK closet type room air conditioner split fault code: E1 1, there are obstacles in front condenser 2, the control circuit Xun Chang 3, three-phase power phase 3, the outdoor ambient temperature higher than 43 degrees start cooling 4, Working current Ambassador had protector action or high-pressure pipe pressure Ambassador high voltage switching operation E2 1, indoor fan does not turn or outlet blocked 2, the indoor ambient temperature is below 18 degrees 3, the tube temperature thermal head fracture 4, the tube temperature thermal head plug not plugged in 5, the control circuit Xun Chang 6, the capacitor C7 leakage E3, low-voltage protection E4. Compressor discharge temperature protection E5, low-voltage protection (stall overcurrent protection) E6, electrostatic dust protection Gree code! KF-60L WAK closet type room air conditioner split fault code: E1 1, there are obstacles in front condenser 2, the control circuit Xun Chang 3, the outdoor ambient temperature higher than 43 degrees start cooling 4, the high-pressure pipe pressure Ambassador high voltage switching operation E2 1, indoor fan does not turn or outlet blocked 2, the indoor ambient temperature is below 18 degrees 3, the tube temperature thermal head fracture 4, the tube temperature thermal head plug not plugged in 5, the control circuit Xun Chang 6, the capacitor C7 leakage LF-12WAK closet type room air conditioner split fault code: E1 1, there is an obstacle before the condenser 2, the control circuit Xun Chang 3, three-phase power phase 4, when the outdoor temperature is higher than 43 degrees start cooling 5, the working current Ambassador had protector action or high-pressure pipe pressure Ambassador high voltage switching E2 1, indoor fan does not turn or outlet blocked 2, the indoor ambient temperature is below 18 degrees 3, the tube temperature thermal head fracture 4, the tube temperature thermal head plug not plugged in 5, the control circuit Xun Chang 6, the capacitor C7 leakage Gree E1 E2 press high pressure system presses antifreeze E3 E4 low pressure exhaust press press press 2 overload b1D High pressure system antifreeze b2 b3 b4 press low pressure compressor overload Press exhaust b5 b6 b7 evaporator condenser probe sensor EC communication failure EE memory chip failure low pressure compressor C2 C3 C4 system antifreeze press exhaust C5 C6 condensate press overload Sensor C7 evaporator sensor F0 indoor environmental sensor F1 evaporator condenser probe sensor F2 F5 F3 outdoor ambient sensor exhaust gas sensor exhaust gas sensor fault F6 F7 F9 Fan overcurrent exhaust gas sensor Gree air-conditioning fault code! KF-60L WAK closet type room air conditioner split fault code: E1 1, there are obstacles in front condenser 2, the control circuit Xun Chang 3, the outdoor ambient temperature higher than 43 degrees start cooling 4, the high-pressure pipe pressure Ambassador high voltage switching operation E2 1, indoor fan does not turn or outlet blocked 2, the indoor ambient temperature is below 18 degrees 3, the tube temperature thermal head fracture 4, the tube temperature thermal head plug not plugged in 5, the control circuit Xun Chang 6, the capacitor C7 leakage LF-12WAK closet type room air conditioner split fault code: E1 1, there are obstacles in front condenser 2, the control circuit Xun Chang 3, three-phase power phase 3, the outdoor ambient temperature higher than 43 degrees start cooling 4, Working current Ambassador had protector action or high-pressure pipe pressure Ambassador high voltage switching operation E2 1, indoor fan does not turn or outlet blocked 2, the indoor ambient temperature is below 18 degrees 3, the tube temperature thermal head fracture 4, the tube temperature thermal head plug not plugged in 5, the control circuit Xun Chang 6, the capacitor C7 leakage Gree patio machine Outdoor mechanical and electrical circuit board (light emitting flashes) Cause 26 water level indicator flashes days off (or drain pump damage) 36 wind indicator flashes sweep motor damage 236 lamp blinks choice 25 indicator flashes indoor temperature sensor is damaged 245 indicator blinks Remote Control Problems 35 indicator flashes indoor temperature sensor is damaged 4 clogging indicator flashes center address 2 flashes on the remote control transmitter circuit is open 37 indoor and outdoor lights flashing communication open 27 Air indicator flashes outside communication problems 3467 power indicator light flashes poor contact detection of the main circuit board 23467 power light blinks poor contact detection circuit board 467 indicator flashes compressor suction pressure is too low protection 367 high pressure compressor discharge lamp blinks protection 267 compressor overcurrent indicator flashes 2367 indicator flashes compressor discharge temperature protection 257 indicator flashes compressor discharge temperature problems 357 heat exchanger temperature indicator flashes issues 2457 indicator flashes high voltage switch is open 3457 Hot flashes lights switch open 23457 low voltage switch indicator flashes problem 2357 indicator flashes current detector open or compressor overcurrent protection Gree LF-7.5WPK Display code Cause No power transformer bad display, a power failure, the control circuit or main circuit board failure Boot display 0 degrees indoor temperature sensor failure or C5 ring leakage E1 but phase, outdoor ambient temperature sensor is abnormal or damaged, overcurrent, overvoltage E2 indoor pipe temperature sensor is abnormal, cold protection, capacitor C7 leakage. Gree air-conditioning maintenance One: Gree fixed frequency machine hook sensor resistance is relatively small, that is more accurate, but also the most likely bad common fault will not say say two bad check in:!! About 20 minutes when a refrigerant pressure machine stop; 2 heating outside the fan does not work; great indoor pipe temperature may have been the problem (for all fixed-frequency machine)! Two: Ordinary split type, 1: is the E1 with boxes of performance for a boot immediately stop, in addition to boxes can start other things functions are not used (Simple Solution: The control panel OVC line with the zero line shorted, E1 to the control panel is still bad, do not show that high-voltage protection E1 disconnect switch, etc.) 2: E3 fault some machines simply do not switch low-voltage protection, but also to change all control elements Not solve the problem, the original is now a lot of the control panel are common, LPP line with the zero line shorted as long as the control panel can be! Three: Frequency calm Wang maintenance information 1 exhaust temperature protection: When the T exhaust higher than 115 degrees, press stop, press stop reached less than 90 degrees for three minutes after the resumption of operation; 2 anti-freeze protection: When the tube T is less than -1 degrees, press stop, press stop has reached more than 6 degrees three minutes to resume operation; 3 over-current protection: When I total is greater than D, press stop, external fan stop delay 30 seconds Cooling 32 machine D = 10A, 25 machine D = 8A; 32 machine heating D = 13A, 25 machine D = 10A 4 Overload protection: When the T-tube is greater than 62 degrees, according to the set wind speed within the fan run, press stop. T tube: outdoor heat exchanger temperature cooling, heating when the indoor heat exchanger temperature. 5 indoor and outdoor fault display: D1, D2, D3 of the machine lamp, LED1 (green) LED2 (Red) LED3 (yellow) for the external machine lights. A press stop and when there is a fault LED1 bright; B when the outdoor temperature is faulty LED3 light; LED2 lights when C outdoor pipe temperature is faulty; D module LED1 flashes when protection; E press overload when LED2 and LED3 blink simultaneously; F When the exhaust gas temperature is faulty LED1, LED2, LED3 full brightness; G indoor D1 presses running lights; H Indoor D2 when communication indication flashes normal; I D3 is indoor thermal package indicator flashes when there is a fault. 6 power module fast: each line function Line 1: negative end of the W-phase control signal; Line 2: positive end W control signal; Line 3: the negative terminal of the control signal V; Line 4: V positive terminal of the control signal; Line 5: negative terminal U of the control signal; Line 6: U positive terminal of the control signal; Line 7: ground; Line 8; + 5V line; Line 9: + 12V line; Line 10: protected signal line module (module protection are: overheating, overcurrent, undervoltage protection, the module output signal when there is a very microseconds protection) Four: Frequency Guiji E1-E5 E1: press overcurrent, overheating, excessive exhaust, module protection; E2: indoor anti-freeze protection; E3: indoor temperature thermal package open, short circuit; E4: indoor pipe temperature start, short circuit; E5: indoor and outdoor communication failure. Five: fixed-frequency machine fault codes: E1: Compressor high pressure protection E2: Evaporator anti-freeze protection E3: Compressor voltage protection E4: compressor discharge temperature protection E5: over-current (low voltage protection) Product Specifications: Maintenance Quantity: Open Packing
Haier inverter air conditioner repair fault code:
1, KFR-26GW / BPF, KFR-26GW / A, KFR-26GW / C (BPF), KFR-28GW / BPA, KFR-28GW / BPF, KFR-28GW / A (BPF), KFR-28GW / C ( BPF), KFR-40GW / BPF, KFR-40GW / A (BPF), KFR-28GW / DBPF, KFR-36GW / DBPF, KFR-28GW / M (BPF), KFR-36GW / M (BPF), KFR- 25GW * 2 / BP, KFR-25GW * 2 / BPF, KFR-25GW * 2 / BPJF, KFR-26GW * 2 / BPF, KFR-30GW * 2 / BPF, KFR-30GW * 2 / BPKF, KR- (32G / AF. 40G / F) 60W / BP, KR- (32G / AF. 50L / F) 70W / BP Indoor Indicators Probable cause Power timed operation Flash Off Off indoor ambient temperature sensor Bright flash lit indoor heat exchanger sensor Bright flash lit outdoor defrost sensor Flash light off the press exhaust gas temperature sensor Flash Off Outdoor sensor error Flash Off press abnormal operation Shining bright 1. DC current detecting overcurrent protection operation 2. 3. 4. The power module temperature protection detecting low voltage power module Indoor Indicators Probable cause Power timed operation Flash flash off the overcurrent protection operation AC current detecting When Winky flash heating, evaporator temperature rise (above 68 degrees), or a small amount of indoor air blower Flash off flash CT disconnection protection Bright shiny power module exception Off Off Flash Communication Abnormal Off flash off the exhaust pipe temperature exceeds 120 degrees Explain the reasons for insufficient flash off voltage, allowing users to power off 10-15 minutes after power is turned on again Flash control substrate abnormal Off Off bright flash indoor unit EEPROM error Flash bright flash outdoor unit EEPROM exception 2, KFR-35GW / BPF, KFR-35GW / ABPF, KFR-36GW / BP, KFR-36GW / BPF, KFR-36GW / ABPF, KFR-50GW / BPF, KFR-50LW / BP, KFR-50LW / BPF Symptom Cause Timing lights flashing 1 Power Module overtemperature, overcurrent, short circuit Timing lights flash 2 times the current sensor induced current is too small Timer lamp 4 flashes when heating press temperature sensor temperature exceeds 120 degrees protection Timing lights flash five times over-current protection Timing lights flash 6 times outdoor ambient temperature sensor fault Timer lamp blinks 7 times outdoor heat sensor failure The timing light flashes 10 times super power, undervoltage The timing light flashes 11 times the instantaneous power failure protection The timing light flashes 12 times when the outdoor heat exchanger cooling sensor temperature exceeds 70 degrees protection The timing light flashes 14 times microcontroller EEPROM data read errors The timing light flashes 15 times when the instantaneous power device reset Symptom Cause Power light flashes once indoor ambient temperature sensor fault Power light blinks twice indoor heat sensor failure Power light blinks four times when the indoor heat exchanger heating sensor temperature exceeds 72 degrees protection Power light blinks five times the cooling indoor heat exchanger sensor temperature is below 0 degrees protected Power light blinks six times a transient power outage device reset Power light blinks 7 times communication circuit failure Power LED flashes eight times indoor fan failure Instantaneous power light blinks 9 times power failure protection 3, KFR-36GW / B (BPF), KFR-36GW / BPJF, KFR-28GW / BPJF, KFR-28GW / (BPF) KFR-36GW / (BPF) Indoor display Cause E1 indoor ambient temperature sensor E2 indoor heat exchanger temperature sensor F21 Outdoor defrost temperature sensor F25 outdoor exhaust gas temperature sensor F6 outdoor ambient temperature sensor E07 Communication error Indoor display Cause F24 CT disconnection F4 exhaust gas temperature exceeds 120 ℃, the exhaust pipe overheat protection F22 AC current overcurrent protection F23 DC current overcurrent protection E9 heating, the evaporator temperature rise (68 ℃ above), or indoor motor is running but the small amount of wind Press F11 abnormal operation 4. KFR-60LW / BPF Fault Display Cause E1 temperature sensor fault E2 indoor coil sensor failure Outdoor ambient temperature sensor failure E3 E4 outdoor coil sensor failure E5 overcurrent protection E6 press overheat protection E7 Outdoor Low Voltage Protection E8 panel and motherboard communication failure E9 indoor and outdoor communication failure 5. KFR-48LW / @ (BPJXF), KFR-48LW / @ (BPF), KFR-50LW / BPJXF, KFR-51LW / BPJXF, KFR-51LW / BPJF, KFR-51LW / N (BPF), KFR-51LW / T (BPJXF), KFR-51LW / @ (BPJXF), KFR-52LW / BPJXF, KFR-52LW / BPJF, KFR-52LW / E (BPJXF), KFR-52LW / N (BPJXF), KFR-58LW / T (BPJXF), KFR-58LW / @ (BPF), KFR-58LW / @ (BPJXF), KFR-60LW / BPJXF, KFR-58LW / BPJXF, KFR-58LW / E (BPJXF), KFR-58LW / N (BPJXF ), KFR-58LW / N (BPF), KFR-60LW / BPJF, KFR-60LW / BPXF, KFR-60LW / E (BPJXF), KFR-68LW / BPJXF, KFR-68LW / E (BPJXF), KFR-68LW / @ (BPJXF), etc. Fault code Cause E1 power module overheating, overcurrent, short circuit E2 current sensor induced current is too small When E4 heating press temperature sensor temperature exceeds 120 ℃ E5 overcurrent protection E6 outdoor temperature sensor fault E7 outdoor coil sensor failure Ea power over Brown Ec cooling when outdoor heat exchanger sensor temperature exceeds 70 ℃ protection Ee microcontroller EEPROM data read errors F1 room temperature sensor fault F2 indoor coil sensor failure F4 heating when the indoor coil sensor 超过 72 ℃ protection F5 cooling the indoor coil temperature sensor is below 0 ℃ protection F7 indoor communication failure with the control panel board Haier fixed-frequency air-conditioning repair fault code KFR-26GW / B (JF), KFR-26GW / (JF), KFR-36GW / B (JF), KFR-36GW / C (F) KFR-40GW / A (JF) Fault code Cause E1 indoor environmental sensor open circuit, short circuit, poor contact E2 Indoor coil sensor open circuit, short circuit, poor contact E21 defrost temperature sensor error E4 microcontroller reads the EEPROM data error E8 between panel and control board communication failure E14 indoor fan failure E16 in ion dust fault E24 CT current transformer fault protection circuit board CT current transformer bad coil, replace the circuit board, the compressor does not start, compressor current, leak Haier fixed frequency Guiji repair fault code KFRD-52LW / JXF, KFRD-62LW / F, KFRD-62LW / JXF, KFRD-71LW / F, KFRD-71LW / SDF, KFRD-71LW / JXF, KFRD-120LW / F Fault code Cause E1 temperature sensor fault E2 indoor coil sensor failure Outdoor ambient temperature sensor failure E3 E4 outdoor coil sensor failure E5 overcurrent protection E6 pipeline pressure protection E7 Outdoor Low Voltage Protection E8 panel and motherboard communication failure E9 indoor and outdoor communication failure Mitsubishi Heavy Industries - Haier Guiji repair fault code Symptom Detecting light (yellow) Fault code Cause E1 panel and indoor board communication failure Shiny 1st E6 indoor ambient temperature sensor failure sensor resistance wrong, bad inner panel Shiny 2nd E7 indoor coil sensor failure Blinks 4 times E9, E40 outdoor unit abnormal voltage low, high pressure, high voltage switching operation E57 flashes five times less pressure refrigerant detection Flashes 6 times E8 outdoor unit refrigerant through excessive load protection, short circuit On the control panel SW13-6 setting error E28 will SW13-6 set to off (OFF) detection lamp (yellow) Fault code Cause E1 panel and indoor board communication failure Shiny 1st E6 indoor ambient temperature sensor failure sensor resistance wrong, bad inner panel Shiny 2nd E7 indoor coil sensor failure Blinks 4 times E9, E40 outdoor unit abnormal voltage low, high pressure, high voltage switching operation E57 flashes five times less pressure refrigerant detection Flashes 6 times E8 outdoor unit refrigerant through excessive load protection, short circuit On the control panel SW13-6 setting error E28 will SW13-6 set to off (OFF Indoor unit The number of continuous power indicator flashing fault code on behalf of the indoor unit The following figures represent the number of times The indoor unit malfunction 1 room temperature sensor-related fault 2 indoor coil sensor-related fault 4 heating indoor coil overheating or sensor failure 5 refrigeration or cold indoor coil sensor failure 6CPU not working properly 7 communication failure 8 internal fan failure (Hall element containing bad) 9 bad power supply Indoor unit The number of timer lamp (yellow) Continuous flashing fault code on behalf of the outdoor unit The following figures represent the number of times The outdoor unit malfunction 1IPM module overtemperature, overcurrent, short circuit 2 outdoor compressor without electricity (galvanometer coil, compressor open, etc.) 4 compressor overheating 5 whole overcurrent 6 outdoor ambient temperature sensor relevant parts 7 outdoor coil sensor relevant parts 8CPU fault 10 Power undervoltage 11 bad power supply 12 refrigeration outdoor coil temperature exceeds 72 degrees 14CPU fault 15CPU working conditions are not normal or CPU bad Inverter air conditioner fault code 1, KFR-26GW / BPF, KFR-26GW / A (BPF), KFR-26GW / C (BPF), KFR-28GW / BPA, KFR-28GW / BPF, KFR-28GW / A (BPF), KFR-28GW / C (BPF), KFR-40GW / BPF, KFR-40GW / A (BPF), KFR-28GW / DBPF, KFR-36GW / DBPF, KFR-28GW / M (BPF), KFR-36GW / M (BPF) , KFR-25GW * 2 / BP, KFR-25GW * 2 / BPF, KFR-25GW * 2 / BPJF, KFR-26GW * 2 / BPF, KFR-30GW * 2 / BPF, KFR-30GW * 2 / BPKF, KR - (. 32G / AF 40G / F) 60W / BP, KR- (. 32G / AF 50L / F) 70W / BP Indoor display reasons lamp fault repair method Remarks Power timed operation Flash Off Off indoor temperature sensor ring home maintenance Sparkling indoor heat sensor 1. onsite inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul Bright flash outdoor home maintenance defrost sensor is only applicable to a drag of a model Shining off the press exhaust gas temperature sensor 1, home inspection filter is dirty, heat exchanger is normal, pipeline installation is intact 2. Check the sensor resistance 3, if the above normal, back overhaul Bright flash off the outdoor temperature sensor home maintenance Flash off on outdoor sensor abnormality home maintenance applies only to one with two models Flash Off press abnormal operation 1, on-site detection voltage is normal, the pipeline is installed intact; 2. If more than normal, back to overhaul applies only to a drag of a model Shining bright 1. DC current detecting 2, over-current protection action 3, power module temperature protection 4, detecting the low voltage power module 1, on-site detection voltage is normal. 2, the voltage is normal, back to overhaul Indoor display reasons lamp fault repair method Power timed operation Shining off the overcurrent protection operation AC current detecting 1, on-site detection voltage is normal; 2, the voltage is normal, back to overhaul When Winky flash heating, evaporator temperature rise (above 68 degrees), or a small amount of indoor air blower 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, if the above normal, back overhaul Flash off flash CT disconnection protection home maintenance Bright shiny power module exception home maintenance Off Off abnormal flash communication home maintenance Off flash off the exhaust pipe temperature exceeds 120 degrees 1, home inspection filter is dirty, heat exchanger is normal, pipeline installation is intact 2. Check the sensor resistance 3, if the above normal, back overhaul Explain the reasons for insufficient flash off voltage, allowing users to power off 10-15 minutes after power is turned on again Flash control substrate abnormal Off-site maintenance Off bright flash EEPROM abnormal indoor home maintenance Shiny flash outdoor unit EEPROM exception home maintenance 2, KFR-35GW / BPF, KFR-35GW / ABPF, KFR-36GW / BP, KFR-36GW / BPF. KFR-36GW / ABPF, KFR-50GW / BPF, KFR-50LW / BP, KFR-50LW / BPF Symptom Cause Repair method Remarks Timing lights flashing 1 Power Module overtemperature, overcurrent, short circuit back to the maintenance of the outdoor unit Timing lights flash 2 times the current sensor induced current is too small on-site maintenance Timer lamp 4 flashes when heating press temperature sensor temperature exceeds 120 degrees protection 1, home inspection is normal heat exchanger, piping installation is intact; 2. Check the press sensor resistance 3, if the above normal, back overhaul Timing lights flash five times over-current protection 1, on-site detection voltage is normal; 2, the voltage is normal, back to overhaul Timing lights flash 6 times outdoor ambient temperature sensor fault home maintenance Timer lamp blinks 7 times outdoor heat sensor failure home maintenance The timing light flashes 10 times power super, undervoltage explain why, allowing users to power again after 10-15 minutes, turn on the power Power is turned on again the timing light flashes 11 times to explain why instantaneous power failure protection, allowing users to power off after 10-15 minutes The timing light flashes 12 times when the outdoor heat exchanger cooling sensor temperature exceeds 70 degrees protection 1, home inspection heat exchanger is normal; 2, the sensor resistance 3, if the above normal, back overhaul Timing lights flash microcontroller 14 reads EEPROM data error home maintenance The timing light flashes 15 times when the instantaneous power device reset Turn on the power again to explain why, allowing users to power off after 10-15 minutes Symptom Cause Repair method Remarks Power light flashes once indoor ambient temperature sensor fault indoor home maintenance power light blinks twice indoor heat sensor failure 1. Check the sensor resistance; 2, check whether the filter is dirty, heat exchanger is normal, the wind speed is normal; 3, if the above normal, back overhaul Power light blinks four times when the indoor heat exchanger heating sensor temperature exceeds 72 degrees protection 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul Power light blinks five times the cooling indoor heat exchanger sensor temperature is below 0 degrees protected 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul MCU reset explain the power light blinks six times a transient power outage reasons, allowing users to power again after 10-15 minutes, turn on the power Power light blinks 7 times communication circuit fault home maintenance Power LED flashes eight times indoor fan fault home maintenance Re-power power power light blinks 9 times to explain why instantaneous power failure protection, allowing users to power off after 10-15 minutes 3, KFR-36GW / B (BPF), KFR-36GW / BPJF, KFR-28GW / BPJF, KFR-28GW / (BPF), KFR-36GW / (BPF) Indoor show the cause maintenance methods E1 indoor ambient temperature sensor home maintenance E2 indoor heat exchanger temperature sensor 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul F21 Outdoor defrost temperature sensor home maintenance F25 outdoor exhaust gas temperature sensor 1, home inspection filter is dirty, heat exchanger is normal, pipeline installation is intact 2. Check the sensor resistance 3, if the above normal, back overhaul Outdoor ambient temperature sensor F6 home maintenance E07 Communication Abnormal home maintenance Indoor show the cause maintenance methods F24CT broken home maintenance F4 exhaust gas temperature exceeds 120 ℃, the exhaust pipe overheat protection 1, home inspection filter is dirty, heat exchanger is normal, pipeline installation is intact 2. Check the sensor resistance 3, if the above normal, back overhaul F22AC current overcurrent protection 1, on-site detection voltage is normal; 2, the voltage is normal, back to overhaul F23DC current overcurrent protection 1, on-site detection voltage is normal; 2, the voltage is normal, back to overhaul E9 heating, the evaporator temperature rise (68 ℃ above), or indoor motor is running but the small amount of wind 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul Press F11 abnormal operation back overhaul E8 panel board communication abnormal home maintenance 4. KFR-60LW / BPF Fault Display Cause repair method E1 temperature sensor fault home maintenance E2 indoor coil sensor failure 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul Outdoor ambient temperature sensor failure E3 home maintenance E4 outdoor coil sensor failure home maintenance E5 overcurrent protection 1, on-site detection voltage is normal; 2, the voltage is normal, back to overhaul E6 press overheat protection 1, home inspection filter is dirty, heat exchanger is normal, pipeline installation is intact 2. Check the press sensor resistance 3, if the above normal, back overhaul E7 Outdoor explain why low-voltage protection, allowing users to power again after 10-15 minutes, turn on the power Communication fault with the motherboard panel E8 home maintenance E9 indoor and outdoor home maintenance communication failure 5, KFR-48LW / @ (BPJXF), KFR-48LW / @ (BPF), KFR-50LW / BPJXF, KFR-51LW / BPJXF, KFR-51LW / BPJF, KFR-51LW / N (BPF), KFR-51LW / T (BPJXF), KFR-51LW / @ (BPJXF), KFR-52LW / BPJXF, KFR-52LW / BPJF, KFR-52LW / E (BPJXF), KFR-52LW / N (BPJXF), KFR-58LW / BPJXF , KFR-58LW / E (BPJXF), KFR-58LW / N (BPJXF), KFR-58LW / N (BPF), KFR-58LW / T (BPJXF), KFR-58LW / @ (BPF), KFR-58LW / @ (BPJXF), KFR-60LW / BPJXF, KFR-60LW / BPJF, KFR-60LW / BPXF, KFR-60LW / E (BPJXF), KFR-68LW / BPJXF, KFR-68LW / E (BPJXF), KFR-68LW / @ (BPJXF), etc. Faulty code Fault repair method E1 power module overheating, overcurrent, short circuit back overhaul E2 current sensor induced current is too small home maintenance When E4 heating press temperature sensor temperature exceeds 120 ℃ 1, home inspection filter is dirty, heat exchanger is normal, pipeline installation is intact; 2. Check the press sensor resistance; 3, if the above normal, back overhaul E5 overcurrent protection 1, on-site detection voltage is normal; 2, the voltage is normal, back to overhaul Outdoor temperature sensor failure E6 home maintenance Outdoor coil sensor failure E7 home maintenance Ea power over undervoltage explain why, allowing users to power off 10-15 minutes after power is turned on again Ec cooling when outdoor heat exchanger sensor temperature exceeds 70 ℃ protection 1, home inspection filter is dirty, heat exchanger is normal; 2, the sensor resistance; 3, if the above normal, back overhaul Ee microcontroller EEPROM data read errors home maintenance F1 home maintenance room temperature sensor fault F2 indoor coil sensor failure 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul F4 heating when the indoor coil sensor 超过 72 ℃ protection 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul F5 cooling the indoor coil temperature sensor is below 0 ℃ protection 1, home inspection filter is dirty, heat exchanger is normal, the wind speed is normal; 2, the sensor resistance 3, if the above normal, back overhaul F7 indoor board communication failure with the control panel home maintenance E1 indoor temperature sensor E2 Outdoor coil sensor E3 outdoor temperature sensor E4 outdoor coil sensor E5 overcurrent E6 pressure protection E7 Low Voltage Protection E8 panel, the motherboard (internal) communication failure E9 indoor and outdoor board communication failure Haier commercial air conditioning (KTR series): The indoor unit 1, a room temperature sensor (TA) circuit 'OC' 2, the indoor heat exchange sensor (TC1) circuit '93' 3, the indoor heat exchanger sensor (TC2) circuit '94' 4, chamber pressure sensor circuit 'b9' 5, the motor circuit (Phase Control) '11' 6, the drain pump, float switch system circuit '0b' 7, the refrigerant circulation amount is less than Analyzing '9F' 8, indoor and outdoor communication circuit '95' 9, centralized control communication circuit '97' 10, central control address setting '98' 11, the external input display 'b5' 12, external Chains Show 'b6' 13, the indoor unit incorrect wiring misconnection '9A' 14, the indoor circuit board '12' 15, the system refrigerant deficiency judgment 'Ed I / F control board 1, frequency serial signal circuit, TRS circuit '04' 2, the outdoor heat exchanger sensor (TE) circuit '18' 3, inverter compressor exhaust temperature sensor (TD1) circuit 'A0' 4, the fixed-frequency press exhaust gas temperature sensor (TD2) circuit 'A1' 5, the intake air temperature sensor (TS) circuit 'A2' 6, the high pressure sensor (Pd) circuit 'AA' 7, the low pressure sensor (Ps) circuit 'b4' 8, the interface substrate circuit '1C' 9, high-voltage protection action (Pd) sensor '22' 10, the inverter compressor discharge temperature (TD1) protective operation 'A6' 11, fixed-frequency press exhaust temperature (TD2) protection action 'bb' 12, suction temperature (Ts) protected action 'A7' 13, when the low-frequency press the exhaust gas temperature (TD1) protective operation 'AE' 14, low pressure protection action 'bE' 15, fixed-frequency switching circuit using a high pressure press 'E1' 16, inverter IOL circuit 'E5' 17, fixed-frequency machine IOL. OL circuit, outdoor unit three-phase phase sequence anomaly 'E6' 18, a pressure sensor (Pd, Ps) miswiring 'Ab' 19 indoor and outdoor communication circuit '95' 20 indoor and outdoor address contradictions '96' 21, MgSW1 contact adhesion control display 'bd' 22, connecting the indoor unit capacity overload '89 E0- drainage system fault E1- indoor temperature sensor fault E2- indoor coil sensor failure E3- outdoor ambient temperature sensor fault E4- outdoor coil sensor failure E5- overcurrent protection E6- pipeline pressure protection E7- panel and motherboard communication failure E8- motherboard and outdoor communication failure
United States of inverter air conditioner fault code Summary First, the frequency split type 1, KFR-28GW / BPY, KFR-32GW / BPY, KFR-45GW / BPY indoor unit fault indication 1.1 indoor unit fault display KFR-28GW / BPY, KFR-32GW / BPY, KFR-45GW / BPY indoor unit fault indication Defrost timer lamp lights automatically lights running lights LED status * * • • Module protection • * * • Compressor top temperature protection * • * • the outdoor temperature sensor is open or shorted • * • • cooling or heating the outdoor temperature is too low, the outdoor temperature is too high * • • • voltage is too high or too low protection • • * • Current Protection • • • • indoor room temperature, evaporator temperature sensor is open or shorted • * • • indoor evaporator temperature protection or low temperature protection * • • • Dehumidification mode to protect the indoor temperature is too low • • • • fan speed out of control • * • • zero crossing detection error • • * • temperature protection fuse off • • • • models do not match • • • • indoor unit and outdoor unit communication protection • ---- * ---- put bright flash • ---- 1.2 MPU outdoor LED display L4 run / standby indicator: Run Standby ---- ---- long bright flashes KFR-28GW / BPY, KFR-32GW / BPY, KFR-45GW / BPY outdoor MPU fault indication L3 L2 L1 fault description ① ② ③ (LED lights from left to right) * * * normal operation • • • Normal Standby * * • Current Protection * • • ambient temperature sensor fault • * • coil temperature sensor failure • • • Outdoor voltage is too high or too low * • * IPM module protection * • • Press top temperature protection • * * two minutes communication failure protection * • * Preheat • - Steady • - Flashing * - Off 2, KFR-26GW / I1BPY, KFR-32GW / I1BPY, KFR-26GW / CBPY, KFR-32GW / CBPY inverter split type 2.1 indoor unit fault display KFR-26GW / I1BPY, KFR-32GW / I1BPY, KFR-26GW / CBPY, KFR-32GW / CBPY indoor unit the indoor unit fault indication fault indication Defrost timer lamp lights automatically light (or ventilation lamp) Note 1 running light LED status * * • • Module protection • * * • Compressor top temperature protection * • * • the outdoor temperature sensor is open or shorted * • • • voltage is too high or too low protection • • • • 室内房间温度, 蒸发器温度传感器开路或短路 • • • • 风机速度失控 • *• • 过零检测出错 • • *• 温度保险丝断保护 * *• • EEPROM参数错误指示 • • • • 机型不匹配 • • • • 室内机和室外机通信保护 •--常亮 •--闪烁 *--常灭 注1: 对KFR-26GW/ I1BPY, KFR-32GW/ I1BPY为自动灯; 对KFR-26GW/ CBPY, KFR-32GW/ CBPY为自动换气及连续换气灯; 2.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 3, KFR-26GW/ BPY-R, KFR-35GW / BPY-R, KFR-26GW/ BPY-S, KFR-35GW/ BPY-S, KFR-26GW/ BPUYP-V, KFR-32GW/ BPUYP-V变频分体机 3.1 室内机故障显示 KFR-26GW/ BPY-R, KFR-35GW/ BPY-R, KFR-26GW/ BPY-S, KFR-35GW/ BPY-S室内机故障指示 显示内容 故障或保护 E0 EEPROM参数错误 E1 室内外机通信故障 E2 过零检测出错 E3 风机速度失控 E4 温度保险丝断保护 E5 室外温度传感器故障 E6 室内温度传感器故障 P0 模块保护 P1 电压过高或过低保护 P2 压缩机顶部温度保护 3.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 3.3 KFR-26GW/ BPY-R1, KFR-35GW/ BPY-R1室内机故障指示 化霜灯 定时灯 干燥防霉灯 强劲灯 LED状态 • X X X EEPROM参数错误 • O O O 模块保护 • O X X 压缩机顶部温度保护 • X X O 室外温度传感器开路或短路 • X O O 电压过高或过低保护 • X O X 室内温度传感器开路或短路 • O X O 风机速度失控 • O O X 过零检测出错 • • • • 室内机和室外机通信保护 备注: O---常亮 •---2HZ闪烁 X---常灭 4, KFR-26GW/ BP2UYP-U, KFR-32GW/ BP2UYP-U, KFR-26GW/ BP2UYP-V, KFR-32GW/ BP2UYP-V 直流变频 分体机 4.1 室内机故障显示 KFR-26GW/ BP2UYP-U, KFR-32GW/ BP2UYP-U, KFR-26GW/ BP2UYP-V, KFR-32GW/ BP2UYP-V室内机故障指示 显示内容 故障或保护 E0 EEPROM参数错误 E1 室内外机通信故障 E2 过零检测出错 E3 风机速度失控 E4 温度保险丝断保护 E5 室外温度传感器故障 E6 室内温度传感器故障 E7 室外风机失速故障 (对V型全直流变频) P0 模块保护 P1 电压过高或过低保护 P2 压缩机顶部温度保护 P3 室外温度过低保护 (预留) P4 压缩机位置检测故障 4.2 室外主控板LED显示 室外有4个LED灯, 分别为电源灯 (LED1) ,状态灯 (LED2, LED3, LED4) 室外机LED显示功能: LED1 电源灯 上电后长亮 LED4 LED3 LED2 故障说明 绿 黄 红 (LED指示灯从左到右) X X X 正常运行 • • • 正常待机 • X X 电流保护 • X X 排气温度传感器故障 • • X 环境温度传感器故障 • X • 冷凝器温度传感器故障 • • • 电压保护 X • X IPM模块保护 • • X 压缩机顶部温度保护 X X • 2分钟通信故障保护 • • • 压缩机驱动保护 • X • 室外直流风机失速保护 备 注: •--常亮 •--闪烁 X--常灭 闪烁频率为2Hz/ s 二, 变频柜机 1, KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY变频柜机 1.1 室内机LCD显示 保护信息代码 (可恢复的保护) KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY室内机故障指示 代码 内容 P01 室内板与室外板2分钟通信不上保护 P02 IPM 模块保护 P03 高低电压保护 P04 室内温度传感器开路或短路 (房间, 温度) P05 室外温度传感器开路或短路 (冷凝器, 环境, 排气温度) P06 室内蒸发器温度保护关压缩机 (高温或低温) P07 室外冷凝器高温保护关压缩机 P08 抽湿模式室内温度过低关压缩机 P09 室外排气温度过高关压缩机 P10 压缩机顶部温度保护 P11 化霜或防冷风 P12 室内风机温度过热 P13 室内板与开关板3分钟通信不上 1.2 室内主控板LED显示 室内机设置5个LED, 其中LED0为工作指示灯, 正常时LED0亮, 异常时LED0以5HZ 的频率闪烁 KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY室内主控板故障指示 LED4 LED3 LED2 LED1 LED0 LED 状态 * * *• • 模块保护 * *• *• 压缩机顶部温度保护 *• * *• 室内房间温度, 蒸发器温度传感器开路或短路 • * * *• 室外温度传感器开路或短路 * *• • • 制冷或制热 室外温度过低, 室外温度过高 *• *• • 排气温度过高 *• • *• 电压过高或过低保护 • *• *• 电流保护 • • * *• 室内蒸发器高, 低温度保护 *• • • • 机型不匹配 • *• • • 抽湿模式室内温度过低保护 • • *• • 室内机和室外机通信保护 • • • *• 室内机和开关板通信保护 • • • • • 温度保险丝断保护 * * * *• 正常状态 (频率值为零) • • * *• 正常状态 (频率值不为零) •----亮 *----熄 •----闪 1.3 室外主控板LED显示 L4 运行/ 待机/ 指示灯: 运行----长亮 待机----0.5HZ闪烁 KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY室内主控板故障指示 L3 L2 L1 故障说明 ① ② ③ (LED指示灯从左到右) * * * 正常运行 • • • 正常待机 * *• 电流保护 *• • 环境温度传感器故障 • *• 盘管温度传感器故障 • • • 室外电压太高或太低 *• * IPM模块保护 *• • 压机顶部温度保护 • * * 二分钟通信故障保护 *• * 预热 •--常亮 •--闪烁 *--常灭 2, KFR-50LW/ F2BPY变频柜机 2.1 室内机故障显示 KFR-50LW/ F2BPY室内机故障指示 LED指示故障 运行灯 定时灯 预热化霜灯 电流保护 * • • 压缩机顶部温度保护 • *• 室外机传感器故障 * * • 室内机温度传感器故障 * • * 模块保护 • * * 电压保护 • • • 室内外机型不匹配 • • * 室内外机通讯保护 • • • •--常亮 •--闪烁 *--常灭 2.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 3. KFR-50LW/ MBPY, KFR-60LW/ MBPY变频柜机 3.1 室内机故障显示 KFR-50LW/ MBPY, KFR-60LW/ MBPY室内机故障指示 保护 内 容 故障 内 容 P1 室内外2分钟通信保护 E1 室内温度传感器故障 P2 模块保护 E2 预留 P3 高低电压保护 E3 预留 P4 室内蒸发器高温或低温保护 E4 室外温度传感器故障 P5 室外冷凝器高温保护 E5 室内板与显示板3分钟通信故障 P6 预留 E6 预留 P7 室外排气温度过高保护 E7 预留 P8 压缩机顶部温度保护 E8 静电除尘故障 P9 化霜 E9 EEPROM故障 3.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 4. KFR-50LW/ BPY-R, KFR-60LW/ BPY-R变频柜机 4.1 室内机故障显示 当空调出现故障时, 温度显示区自动显示故障保护代码5秒钟, 然后隐去, 恢复显示设定温度. 按'试运行'键, 可进入检查状态, 再按'•'或'•'键, 可察看T1 (室内温度) ,T2 (室内管温) ,T3 (室外管温) ,T4 (室外温度) ,故障代码. KFR-50LW/ BPY-R, KFR-60LW/ BPY-R室内机故障指示 保护 内 容 故障 内 容 P1 室内外2分钟通信保护 E1 室内温度传感器故障 P2 模块保护 E2 预留 P3 高低电压保护 E3 预留 P4 预留 E4 室外温度传感器故障 P5 预留 E5 预留 P6 等离子故障 E6 预留 P7 预留 E7 预留 P8 压缩机顶部温度保护 E8 预留 P9 化霜或防冷风 E9 EEPROM故障 4.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 一. 柜机 1. 适用于S系列; K2系列; F2系列; H1系列 保护代码 表示内容 定时灯以5Hz闪烁 T1室温传感器检测口异常 运行灯以5Hz闪烁 T2蒸发器传感器检测口异常 化霜灯以5Hz闪烁 T3冷凝器传感器检测口异常 运行, 定时, 化霜灯同时以5Hz闪烁 室外机保护 注1: 当室外机保护和温度传感器检测口异常同时发生时, 优先指示室外机保护故障. 注2: 强制制冷期间发生室外机保护, 故障清除后恢复到强制制冷状态 2) 适用于E系列柜机 保护代码 表示内容 故障代码 表示内容 P 02 压缩机过载 (保留) E 01 温度传感器开路, 短路故障 P 03 室内蒸发器温度过低 (制冷) E 02 压缩机过流 (保留) P 04 室内蒸发器温度过高 (制热) E 03 压缩机欠流 (第一次上电检) (保留) P 05 室内出风口温度过高 (制热) E 04 室外机保护 E 05 温度传感器开路, 短路故障 注: 故障期间LED以2Hz频率闪, 而保护期间LED显示正常. 3) 适用于S1系列; S2系列; S3系列; S6系列; Q系列; R系列; Q1系列; V系列; Q2 系列; U系列; U1系列柜机 保护代码 表示内容 故障代码 表示内容 P3 高低电压保护 (变频机用) E1 T1传感器故障 P4 室内蒸发器保护关压缩机 (高温或低温) E2 T2传感器故障 P5 室外冷凝器高温保护关压缩机 E3 T3传感器故障 P7 室外排气温度过高关压缩机 (变频机用) E4 T5传感器故障 (变频机用) P8 压缩机顶部温度保护 (变频机用) E5 网络通信故障 P9 化霜保护或防冷风关风机 E6 室外机故障 E7 加湿器 故障 E8 静电除尘故障 E9 自动门故障 PAU 进风格栅保护 二. 分体机 1) 适用于T系列; T1系列; I4系列; 26Z系列; 32Z系列; G系列; 工作灯 定时灯 LED 状态 • X 风机速度失控 (SPABF) 5Hz • O 室内温度和蒸发器温度传感器开路或短路 (PREVP) 5Hz X • 四次电流保护 O • 上电时读EEPROM参数出错 O (亮) X ( 熄) • (闪) 2) 适用于T3系列; T6系列; T2系列; T4系列; T5系列 运行灯 定时灯 故障类型 • X 风机速度失控 • O 室内温度和蒸发器温度传感器开路或短路 X • 四次电流保护 • • 上电时读EEPROM参数出错或过零检测出错 O (亮) X ( 熄) • (闪) 3) 适用于Q1系列; Q2系列; U系列; V系列 故障代码 表示内容 E1 上电时读EEPROM参数出错 E2 过零检测出错 E3 风机速度失控 E4 四次电流保护 E5 室内房间温度传感器开路或短路 E6 室内蒸发器温度传感器开路或短路 4) 适用于I1, A系列 (UPD780021芯片) 工作灯 定时灯 化霜灯 LED 状态 • X • 四次电流保护 • X X 风机速度失控 • • • 过零检测出错 • • O 主芯片和计算机通信不上 X X • 室内蒸发器温度传感器开路或短路 X • X 室内房间温度传感器开路或短路 • • X 温度保险丝断保护 (FUSED) O O O 上电时读EEPROM参数出错 O (亮) X ( 熄) • (闪) (MC68HC908JL3统一芯片方案) 工作灯 定时灯 化霜灯 LED 状态 • X • 四次电流保护 • X X 风机速度失控 • • • 过零检测出错 X X • 室温或管温传感器开路或短路 5) 适用于20Z, 22Z战斗机 (S8M7217统一芯片) ,I2系列; I5系列; Q系列 运行灯 定时灯 故障类型 • X 风机速度失控 • O 室内温度和蒸发器温度传感器开路或短路 X • 四次电流保护 O • 上电时读EEPROM参数出错 • • 过零检测出错 O (亮) X ( 熄) • (闪) 美的全健康Q1型挂机故障代码 显示内容故障类型 E1上电时读EEPROM参数出错 E2过零检测出错 E3风机速度失控 E4四次电流保护 E5室内房间温度传感器开路或短路 E6室内蒸发器温度传感器开路或短路 美的B (C) 型分体落地机故障显示代码 L (R) F-7.5WB (D) L (R) F-12WB L (R) F-7.5WC (D) L (R) F-12WC KF (R) -48LW/ Y KF (R) -61LW/ Y KF (R) -75LW/ B (C) (S) (D) KF (R) -120LW/ B (C) (S) (D) 开关板上的故障类型显示 (开关板上LED1快闪) ,保护恢复后工作正常 故 障 类 型显示代码 室外机故障01 电源过欠压02 制冷时室内蒸发器温度过低03 制热时室内蒸发器温度过高04 室内出风口温度过高05 室内主控板与显示板不能通信06 室内机电路故障07 室外机故障时, 室外LED3快闪, 室外故障类型显示灯 (LED456) 指示故障内容: LED6LED5LED4保护类型 过流保护 ON室外保护 欠流保护 ON 室外保护 管路过压ON 室外保护 管路欠压 ONON室外保护 电压过压ON ON电压过压 电压欠压ONON 电压欠压 相序错误ONONON室外保护 缺A相 •室外保护 缺B相 • 室外保护 缺C相• 室外保护 其它 室外保护 美的A型落地空调器故障指示 LF-8W (单相, 三相) RF-8W (单相, 三相) LF-12W RF-12W 室外故障检测故障指示灯表示的故障类型: 亮 灯 情 况指 示 的 内 容 LED1亮电压过高 LED2亮电压过低 LED3亮管路压力过高, 压缩机过流或过热 LED4亮管路压力过低 LED1和LED2亮室外机温度检测大于80度 LED1和LED3亮室外机温度检测小于-40度 美的KFR-50 (60) LW/ MBPY故障代码 保护代码内 容故障代码内 容 P1室内外2分钟通信保护E1室内温度传感器故障 P2模块保护E2预留 P3高低电压保护E3预留 P4室内蒸发器温度高温或低温保护E4室外温度传感器故障 P5室外冷凝器高温保护关压缩机E5室内板与显示板3分钟通信故障 P6预留E6预留 P7室外排气温度过高保护E7预留 P8压缩机顶部温度保护E8静电除尘故障 P9化霜E9EEPROM故障 美的50FBPY, 50BPY变频柜机代码 开关板显示代码 (其中故障为不可恢复的保护) 代码内 容 E01一个小时四次模块保护 E02 (暂无) E03一个小时三次排气温度保护 P01室内板与室外板2分钟通讯不上保护 P02IPM模块保护 P03高低电压保护 P04室内温度传感器开路或短路 (房间, 温度) P05室外温度传感器开路或短路 (高温或低温) P06室内蒸发器温度保护关压缩机 (高温或低温) P07室外冷凝器高温保护关压缩机 P08抽湿模式室内温度过低关压缩机 P09室外排气温度过高关压缩机 P10压缩机顶部温度保护 P11化霜或防冷风 P12室内风机温度过热 P13室内板与开关板2分钟通讯不上 室内机故障显示功能 (其中LED0为工作指示灯, 正常时LED0亮, 异常时LED0以5HZ的频率闪烁) KFR--40GW/ BPY-R 显示内容 故障或保护定义 E0 参数错误 E1 室内外机通信故障 E2 过零检测出错 E3 风机速度失控 E4 温度保险丝断保护 E5 室外温度传感器故障 E6 室内温度传感器故障 P0 模块保护 P1 电压过高或过低保护 P2 压缩机顶部温度 KFR-26GW/ I1BPY KFR-32GW/ I1BPY 运行时LED的显示一, 正常 1, 工作灯 正常开机时 (工作灯) LED4 亮 正常关机时 (工作灯) LED4 灭 2, 化霜灯 化霜或防冷风功能有效时 (化霜灯) LED1 亮 化霜或防冷风功能无效时 (化霜灯) LED1 灭 3, 定时灯 定时功能有效时 (定时灯) LED2 亮 定时功能无效时 (定时灯) LED2 灭 4, 换气灯 连续换气运行时 (连续换气灯) LED3, LED5 亮 连续换气停止时 (连续换气灯) LED3, LED5 灭 自动换气运行时 (自动换气灯) LED6, LED7 亮 自动换气停止时 (自动换气灯) LED6, LED7 灭 二 室内机故障显示功能 LED4 工作灯 LED2 化霜灯 LED1 定时灯 LED3, LED5 连续换气灯 LED2化霜 LED1定时 LED3567连续, 自动换气 LED4工作 LED 状态 X X O • 模块保护 (PRMOD PRMOD1) O X X • 压缩机顶部温度保护 (PRCOM) X O X • 室外温度传感器开路或短路 (PROUTD) X O O • 电压过高或过低保护 (PRVAC) O O O • 室内房间温度, 蒸发器温度传感器开路或短路 (PREVP , PRROM) O O • • 风机速度失控 (SPABF) • X O • 过零检测出错 (ACBAD) X X • • EEPROM参数错误指示 • O X • 温度保险丝断保护 (FUSED) • O • • 机型不匹配 (TYPER) • • • • 室内机和室外机通信保护 (PRTRN) O (亮) X ( 熄) • (闪) (三) ,室外机 故 障 自 我 诊 断 显 示 只设L4故障指示灯: L4 运行/ 待机指示灯 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 16.2对于KFR-26 (32) GW/ I1BPY, 室内设置4个LED. 分别为工作灯 (LED1) ,化霜灯 (LED5) ,定时灯 (LED6) ,自动灯 (LED3) . 一, 正常运行时LED的显示 1, 工作灯 正常开机时 (工作灯) LED1 亮 正常关机时 (工作灯) LED1 灭 2, 化霜灯 化霜或防冷风功能有效时 (化霜灯) LED5 亮 化霜或防冷风功能无效时 (化霜灯) LED5 灭 3, 定时灯 定时功能有效时 (定时灯) LED6 亮 定时功能无效时 (定时灯) LED6 灭 4, 自动灯 自动功能有效时 (自动灯) LED3 亮 自动功能无效时 (自动灯) LED3 灭 (二) : 室内机故障显示功能 LED4 工作灯 LED2 化霜灯 LED1 定时灯 LED3, LED5 连续换气灯 LED2化霜 LED1定时 LED3自动 LED4工作 LED 状态 X X O • 模块保护 (PRMOD PRMOD1) O X X • 压缩机顶部温度保护 (PRCOM) X O X • 室外温度传感器开路或短路 (PROUTD) X O O • 电压过高或过低保护 (PRVAC) O O O • 室内房间温度, 蒸发器温度传感器开路或短路 (PREVP , PRROM) O O • • 风机速度失控 (SPABF) • X O • 过零检测出错 (ACBAD) • O X • 温度保险丝断保护 (FUSED) X X • • EEPROM参数错误指示 • O • • 机型不匹配 (TYPER) • • • • 室内机和室外机通信保护 (PRTRN) O (亮) X ( 熄) • (闪) (三) ,室外机 故 障 自 我 诊 断 显 示 只设L4故障指示灯: L4 运行/ 待机指示灯 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 机型的系统参数: 1, 工作频率: F0, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10 2, 室内风机转速: 高风档的转速参数 SPEEDH . 中风档的转速参数 SPEEDM . 低风档的转速参数 SPEEDL . 微风档的转速参数 SPEEDS . 3, 欠压, 过压保护 值准入电压 V1 准出电压 限频F1电压 V2 美的空调天朗星触摸屏系列柜机 (M系列) 故障代码 天朗星触摸屏系列柜机 (M系列) 保护代码 内 容 故障代码 内 容 P3 高低电压保护 (变频机用) E1 T1传感器故障 P4 室内蒸发器温度保护关压缩机 (高温或低温) E2 T2传感器故障 P5 室外冷凝器高温保护关压缩机 E3 T3传感器故障 P7 室外排气温度过高关压缩机 (变频机用) E4 T4传感器故障 (变频机用) P8 压缩机顶部温度保护 (变频机用) E5 室内板与显示板3分钟通信不上 P9 化霜保护或防冷风关风机 E6 室外保护 E7 加湿器故障 E8 静电除尘故障 E9 EEPROM出错 美的柜机室外机保护 室外保护: LED3为电源指示灯 LED显示 内 容 LED1 LED2 LED3 灭 灭 亮 正常 亮 灭 亮 相序接反 灭 亮 亮 过电流 亮 亮 亮 缺相 亮 亮 亮 压力保护 ------------------------------------- 美的空调故障代码汇编手册 一, 变频分体机 1, KFR-28GW/ BPY, KFR-32GW/ BPY, KFR-45GW/ BPY室内机故障指示 1.1室内机故障显示功能 KFR-28GW/ BPY, KFR-32GW/ BPY, KFR-45GW/ BPY室内机故障指示 化霜灯 定时灯 自动灯 运行灯 LED 状态 * *• • 模块保护 • * *• 压缩机顶部温度保护 *• *• 室外温度传感器开路或短路 • *• • 制冷或制热 室外温度过低, 室外温度过高 *• • • 电压过高或过低保护 • • *• 电流保护 • • • • 室内房间温度, 蒸发器温度传感器开路或短路 • *• • 室内蒸发器高温保护或低温保护 *• • • 抽湿模式室内温度过低保护 • • • • 风机速度失控 • *• • 过零检测出错 • • *• 温度保险丝断保护 • • • • 机型不匹配 • • • • 室内机和室外机通信保护 •----亮 *----熄 •----闪 1.2 室外主控板LED显示 L4 运行/ 待机指示灯: 运行----长亮 待机----闪烁 KFR-28GW/ BPY, KFR-32GW/ BPY, KFR-45GW/ BPY室外主控板故障指示 L3 L2 L1 故障说明 ① ② ③ (LED指示灯从左到右) * * * 正常运行 • • • 正常待机 * *• 电流保护 *• • 环境温度传感器故障 • *• 盘管温度传感器故障 • • • 室外电压太高或太低 *• * IPM模块保护 *• • 压机顶部温度保护 • * * 二分钟通信故障保护 *• * 预热 •--常亮 •--闪烁 *--常灭 2, KFR-26GW/ I1BPY, KFR-32GW/ I1BPY, KFR-26GW/ CBPY, KFR-32GW/ CBPY变频分体机 2.1 室内机故障显示功能 KFR-26GW/ I1BPY, KFR-32GW/ I1BPY, KFR-26GW/ CBPY, KFR-32GW/ CBPY室内机故障指示室内机故障指示 化霜灯 定时灯 自动灯 (或换气灯) 注1 运行灯 LED 状态 * *• • 模块保护 • * *• 压缩机顶部温度保护 *• *• 室外温度传感器开路或短路 *• • • 电压过高或过低保护 • • • • 室内房间温度, 蒸发器温度传感器开路或短路 • • • • 风机速度失控 2 美的空调 故障代码汇编手册 • *• • 过零检测出错 • • *• 温度保险丝断保护 * *• • EEPROM参数错误指示 • • • • 机型不匹配 • • • • 室内机和室外机通信保护 •--常亮 •--闪烁 *--常灭 注1: 对KFR-26GW/ I1BPY, KFR-32GW/ I1BPY为自动灯; 对KFR-26GW/ CBPY, KFR-32GW/ CBPY为自动换气及连续换气灯; 2.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 3, KFR-26GW/ BPY-R, KFR-35GW/ BPY-R, KFR-26GW/ BPY-S, KFR-35GW/ BPY-S, KFR-26GW/ BPY-R1, KFR-35GW/ BPY-R1, KFR-26GW/ BPUYP-V, KFR-32GW/ BPUYP-V变频分体机 3.1 室内机故障显示 KFR-26GW/ BPY-R, KFR-35GW/ BPY-R, KFR-26GW/ BPY-S, KFR-35GW/ BPY-S, KFR-26GW/ BPY-R1, KFR-35GW/ BPY-R1室内机故障指示 显示内容 故障或保护 E0 EEPROM参数错误 E1 室内外机通信故障 E2 过零检测出错 E3 风机速度失控 E4 温度保险丝断保护 E5 室外温度传感器故障 E6 室内温度传感器故障 P0 模块保护 P1 电压过高或过低保护 P2 压缩机顶部温度保护 3.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 4, KFR-26GW/ BP2UYP-U, KFR-32GW/ BP2UYP-U, KFR-26GW/ BP2UYP-V, KFR-32GW/ BP2UYP-V直流变频分体机 4.1 室内机故障显示 KFR-26GW/ BP2UYP-U, KFR-32GW/ BP2UYP-U, KFR-26GW/ BP2UYP-V, KFR-32GW/ BP2UYP-V室内机故障指示 显示内容 故障或保护 E0 EEPROM参数错误 E1 室内外机通信故障 E2 过零检测出错 E3 风机速度失控 E4 温度保险丝断保护 E5 室外温度传感器故障 E6 室内温度传感器故障 E7 室外风机失速故障 (对V型全直流变频) P0 模块保护 P1 电压过高或过低保护 P2 压缩机顶部温度保护 P3 室外温度过低保护 (预留) P4 压缩机位置检测故障 4.2 室外主控板LED显示 室外有4个LED灯, 分别为电源灯 (LED1) ,状态灯 (LED2, LED3, LED4) 室外机LED显示功能: LED1 电源灯 上电后长亮 LED4 LED3 LED2 故障说明 绿 黄 红 (LED指示灯从左到右) X X X 正常运行 • • • 正常待机 • X X 电流保护 • X X 排气温度传感器故障 • • X 环境温度传感器故障 • X • 冷凝器温度传感器故障 3 美的 空调故障代码汇编手册 • • • 电压保护 X • X IPM模块保护 • • X 压缩机顶部温度保护 X X • 2分钟通信故障保护 • • • 压缩机驱动保护 • X • 室外直流风机失速保护 备 注: •--常亮 •--闪烁 X--常灭 闪烁频率为2Hz/ s 二, 变频柜机 1, KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY变频柜机 1.1 室内机LCD显示 保护信息代码 (可恢复的保护) KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY室内机故障指示 代码 内容 P01 室内板与室外板2分钟通信不上保护 P02 IPM 模块保护 P03 高低电压保护 P04 室内温度传感器开路或短路 (房间, 温度) P05 室外温度传感器开路或短路 (冷凝器, 环境, 排气温度) P06 室内蒸发器温度保护关压缩机 (高温或低温) P07 室外冷凝器高温保护关压缩机 P08 抽湿模式室内温度过低关压缩机 P09 室外排气温度过高关压缩机 P10 压缩机顶部温度保护 P11 化霜或防冷风 P12 室内风机温度过热 P13 室内板与开关板3分钟通信不上 1.2 室内主控板LED显示 室内机设置5个LED, 其中LED0为工作指示灯, 正常时LED0亮, 异常时LED0以5HZ的频率闪烁 KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY室内主控板故障指示 LED4 LED3 LED2 LED1 LED0 LED 状态 * * *• • 模块保护 * *• *• 压缩机顶部温度保护 *• * *• 室内房间温度, 蒸发器温度传感器开路或短路 • * * *• 室外温度传感器开路或短路 * *• • • 制冷或制热 室外温度过低, 室外温度过高 *• *• • 排气温度过高 *• • *• 电压过高或过低保护 • *• *• 电流保护 • • * *• 室内蒸发器高, 低温度保护 *• • • • 机型不匹配 • *• • • 抽湿模式室内温度过低保护 • • *• • 室内机和室外机通信保护 • • • *• 室内机和开关板通信保护 • • • • • 温度保险丝断保护 * * * *• 正常状态 (频率值为零) • • * *• 正常状态 (频率值不为零) 4美的空调故障代码汇编手册 •----亮 *----熄 •----闪 1.3 室外主控板LED显示 L4 运行/ 待机/ 指示灯: 运行----长亮 待机----0.5HZ闪烁 KFR-50LW/ BPY, KFR-50LW/ FBPY, KFR-61LW/ FBPY室内主控板故障指示 L3 L2 L1 故障说明 ① ② ③ (LED指示灯从左到右) * * * 正常运行 • • • 正常待机 * *• 电流保护 *• • 环境温度传感器故障 • *• 盘管温度传感器故障 • • • 室外电压太高或太低 *• * IPM模块保护 *• • 压机顶部温度保护 • * * 二分钟通信故障保护 *• * 预热 •--常亮 •--闪烁 *--常灭 2, KFR-50LW/ F2BPY变频柜机 2.1 室内机故障显示 KFR-50LW/ F2BPY室内机故障指示 LED指示故障 运行灯 定时灯 预热化霜灯 电流保护 * • • 压缩机顶部温度保护 • *• 室外机传感器故障 * * • 室内机温度传感器故障 * • * 模块保护 • * * 电压保护 • • • 室内外机型不匹配 • • * 室内外机通讯保护 • • • •--常亮 •--闪烁 *--常灭 2.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 3 KFR-50LW/ MBPY, KFR-60LW/ MBPY变频柜机 3.1 室内机故障显示 KFR-50LW/ MBPY, KFR-60LW/ MBPY室内机故障指示 保护 内 容 P1 室内外2分钟通信保护 E1 室内温度传感器故障 P2 模块保护 E2 预留 P3 高低电压保护 E3 预留 P4 室内蒸发器高温或低温保护 E4 室外温度传感器故障 P5 室外冷凝器高温保护 E5 室内板与显示板3分钟通信故障 P6 预留 E6 预留 P7 室外排气温度过高保护 E7 预留 P8 压缩机顶部温度保护 E8 静电除尘故障 P9 化霜 E9 EEPROM故障 3.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 4, KFR-50LW/ BPY-R, KFR-60LW/ BPY-R变频柜机 4.1 室内机故障显示 当空调出现故障时, 温度显示区自动显示故障保护代码5秒钟, 然后隐去, 恢复显示设定温度. 按'试运行'键, 可进入检查状态, 再按'•'或'•'键, 可察看T1 (室内温度) ,T2 (室内管温) ,T3 (室外管温) ,T4 (室外温度) ,故障代码. KFR-50LW/ BPY-R, KFR-60LW/ BPY-R室内机故障指示 保护 内 容 故障 内 容 P1 室内外2分钟通信保护 E1 室内温度传感器故障 P2 模块保护 E2 预留 P3 高低电压保护 E3 预留 P4 预留 E4 室外温度传感器故障 P5 预留 E5 预留 P6 等离子故障 E6 预留 P7 预留 E7 预留 P8 压缩机顶部温度保护 E8 预留 P9 化霜或防冷风 E9 EEPROM故障 4.2 室外主控板LED显示 室外只有L4 运行/ 待机/ 指示灯: 运行: 长亮 待机: 0.5HZ闪烁 故障: 1HZ闪烁 美的数智星R型变频柜机故障代码 保护代码 内 容 故障代码 内 容 P1 室内外2分钟通信保护 E1 室内温度传感器故障 P2 模块保护 E2 预留 P3 高低电压保护 E3 预留 P4 预留 E4 室外温度传感器故障 P5 预留 E5 预留 P6 等离子故障 E6 预留 P7 预留 E7 预留 P8 压缩机顶部温度保护 E8 预留 P9 压缩机顶化霜或防冷风 E9 EEPROM故障 美的健康Q1型挂机故障代码 E1上电时, 读EEPROM参数出错 E2过零检测出错 E3风机速度失控 E4四次电流保护 E5室内温度传感器开路或短路 E6室内蒸发管温坏
长虹 空调 故障代码 诊断灯 X灯闪O灯亮•灯灭 1 2 3 X • • 室内温度传感器异常 传感器开路, 短路或接触不良 • X • 室内盘管温度传感器异常 传感器开路, 短路或接触不良 • • X 压机温度传感器异常 传感器开路, 短路或接触不良 X • X 外盘温度传感器异常 传感器开路, 短路或接触不良 • X X 室外温度传感器异常 传感器开路, 短路或接触不良 X X X CT电流异常 HIC不良 (未输出到U, V, W相) O • • 串行通讯异常 配线错, 电源线接触不良, 控制 板坏 • O • HIC过负荷保护 (电流, 温度) HIC不良, 信号线接触不良压机锁住, 磨损严重, 外风机不转, 系统堵塞 O O • 室外用EEPROM故障 OTP数据不良, 接触不良 • • O 电流斩峰 瞬时停电, 电压下降, HIC不良, 压机磨损 O • O 电流异常控制 压机停止 • O O 压机排气温度异常控制 缺R22 (50﹪毛细管堵, 传感器坏, 制冷外风机停止 O O O 室内风扇电机运转异常 电机坏, 驱动电路异常 O X X 四通阀切换异常 四通阀不切换 O X O AC输入电压异常 过欠电压保护动作 室外机CN10插座用法: 1 2 3 T-RUN: 试运转 (压缩机, 外风机, 四通阀接通) COM T-RUN TEST TEST: 所有时间缩短到1/60 机型 故障代码 可能的故障原因 G造型 EO 工作正常 P1 制冷过载 P2 制热过载 F7 温度传感器损坏或异常 (检测各温度) P5 系统异常 KFR-60LW/ DXS EO 工作正常 E1 通讯错误 P1 制冷过载 P2 制热过载 P5 空清异常 F1 高压开关保护 F2 外风机热保护 F3 内风机热保护 F7 温度传感器损坏或异常 (检测各温度) P5 系统异常 H1/ H2/ DF系列 EO 工作正常 P1 制冷过载 P2 制热过载 F7 温度传感器损坏或异常 (检测各温度) P5 系统异常 KFR-120LW/ M KFR-120LW/ MAS KFR-71LW/ M F1 室内机热敏电阻断路或受损 F2 室内机热敏电阻断路或受损 F4 室外机 热敏电阻断路或受损 F5 室外机热敏电阻断路或受损 F6 室外机热敏电阻断路或受损 F7 室外机热敏电阻断路或受损 F8 室外机热敏电阻断路或受损 H1 压缩机电机过载 H2 压缩机电机堵转 H3 压缩机电流检测异常 H6 低压开关动作 (KFR-71LW/ M无) H7 连接室内机和室外机线路或管道接错 48LW系列 60系列 51系列 E1 通信异常 P1 制冷过载 P2 制热过载 P3 系统异常保护 P4 自动模式下室内温度传感异常 长虹 (小清爽) KFR-25GW分体空调故障代码 显示内容故障原因 运行绿 待机黄 定时红5Hz闪上电存储电路错误 定时 (红) 5Hz闪 PG电机或相关电路异常 运行 (绿) 1Hz闪室外管温传感器异常 待机 (黄) 1Hz闪 室内温度传感器异常 定时 (红) 1Hz闪 室内管温传感器异常 长虹G造型空调故障代码 E0 工作正常 P1 制冷过载 P2 制热过载 F7 温度传感器损坏或异常 (检测各温度) P5 系统异常 2 灭 灭 闪 灭 热交传感器 热交传感器插座虚焊或插接不良 3 灭 灭 闪 闪 蒸发器冻结 蒸发器温度过低或风机不转 4 灭 闪 灭 灭 制热 过负荷 制热时温度过高, 超过68度 5 灭 闪 灭 闪 通讯故障 通讯失误时报此故障, 通讯线是否可靠 6 灭 闪 闪 灭 瞬时停电 瞬时有停电现象, 可重新启动 7 灭 闪 闪 闪 过电流 室内机电流过在保护 外机故障代码表: 1 灭 灭 灭 亮 内环温传感器 环温传感器插座接不良 2 灭 灭 亮 灭 热交传感器 热 交传感器插座插接不良 3 灭 灭 亮 亮 压机过热 压机温度过高保护, 冷媒不足 4 灭 亮 亮 灭 过电流 电流异常, 电压异常波动引起 5 亮 灭 灭 灭 电压异常 电压过低和过高时报警 6 亮 灭 灭 亮 瞬间停 电 当供电波形中缺少交流波时 7 亮 灭 亮 灭 制冷 过负荷 外机气温处于过低和过高时报警 8 亮 灭 亮 亮 正在除霜 除霜过程中 9 亮 亮 灭 灭 功率 模块保护 使用时产生过载过热 短路保护, 停机后启动 10 亮 亮 灭 亮 E PROM故障 主板上有虚焊或插接不良 11 亮 亮 亮 灭 低温保护 机型 代码 可能故障原因 F1 室内温度传感器异常 F2 室内盘管温度传感器异常 F3 室外环境温度传感器异常 KFR-45LW/ WDQ F4 室外盘管温度传感器异常 KFR-45LW/ WBQ F5 压缩机排气温度传感器异常 KFR-50LW/ WBQ P1 压缩机排气温度传感器异常 P2 CT电流异常 P4 JPM故障保护 P5 四通阀切换异常 E1 室内主控板与控制面板之间通讯异常 E2 室内主控板与室外控制板之间通讯异常 E1 主控板与面板之间通讯错误 E2 主控板与室外板之间通讯错误 F1 高压开关保护 F2 室外风扇电机热保护器动作 KF-75LW/ WDS F3 室内风扇电机热保护器动作 KF-75W/ W3S F4 低压开关保护 KFR-75LW/ WDES F5 逆相保护 KFR-120LW/ WDS F6 缺相保护 KF-120LW/ WS H1 压缩机过电流保护 H2 压缩机堵转保护 H3 检测不到压缩机电流 P1 制冷过载保护 P2 制热过载保护 0: 工作正常 E1: 主控板与面板之间通信错误 E2: 主控板与面板之间通信错误 P1: 制冷过载 P2: 制热过载 P3: 系统异常 P4: 温度传感器损坏 (可通过查询传感器的值, 来确认损坏的传感器) F1: 高压开关保护 F2: 外风机热保护 F3: 内风机热保护 F4: 低压开关保护 F5: 逆相保护 F6: 缺相保护 H1: 压缩机过电流保护 H2: 压缩机堵转保护 0: 工作正常 E1: 主控板与面板之间通信错误 E2: 主控板与面板之间通信错误 P1: 制冷过载 P2: 制热过载 P3: 系统异常 P4: 温度传感器损坏 (可通过查询传感器的值, 来确认损坏的传感器) F1: 高压开关保护 F2: 外风机热保护 F3: 内风机热保护 F4: 低压开关保护 F5: 逆相保护 F6: 缺相保护 H1: 压缩机过电流保护 H2: 压缩机堵转保护 H3: 检测不到压缩机电流护) 机型 序号 整机故障现象 印制板故障现象 故障位号 'KFR-36GW/ D ( KFR-35GW / WDS与其基本相同) ' 1 不通电 不通电 D1-D4, D5, D6, D9短路, IC6短路, 保险管开路 2 无风 电机不转 DC10变质 3 无风 电机抖动, 无+8.2V 调节R28 4 压缩机工作一会停机 无压缩机CT电流 CT1开路 大清快EQ系列 1 不通电 (通电指示灯不亮) 不通电 C1, C4, C19变质, T1, R4, R60开路, VDZ2, D3, VD4, VD6, VD3, VD2, VD16, VD17. VC1短路 2 无风 遥控大电机不转 VD1, VD15, D6, V3, R10失效 3 工作一会停机, 指示灯闪 工作一会电机停, 指示灯闪 V2变质 4 不工作 不通电 (无晶振电压) C10, C11变质 'KFR-28GW/ BP模块 (KFR-28GW/ BMF同) ' 1 室外压缩机不启动 压机不动 模块短路或参数失调及开路 2 外机不工作 外机不通电 E2失效, BT1, R2开路, Z1短路 'KFR-28G/ BP (KFR-28G/ BMF同) 室内主板' 1 不停机 通电室内电机就转 C503, IC203失效 2 不通电 不通电 F504, RL401失效 3 室内机不工作 电机不转 DQ201失效 KFR-28W/ BMF 1 室外机不工作 不通电 F101, F102, RT201开路, K505失效 2 室外压缩机不工作 压缩机不启动 D303, D301失效, R504, R509开路, D403, T202失效 3 外机不工作 (无通讯) 外机不动 L102, C207, C205, D400, D402失效, D303失效 KFR-28W/ BP 1 室外风扇不转 风机不转 C501变质, RL502, RL503, IC401失效 2 外机不通电 不通电 FUSE101, FUSE102, PTC501开路 3 室外压缩机不工作 压缩机不动 R504, R509, BT202, PC401失效 4 不工作 (无通讯) 无通讯 PC400, PC402失效, R502开路 5 工作一会停机 压缩机启动一会就停 BT202, C207, C205失效 KFR-60L/ WDES 1 不工作 E1故障 V104, V105变质或虚焊 KFR-71L/ WDS 1 不通电 不通电 IC102, IC103失效, L102, D122开路 2 不工作 不叫 (E1故障) Q104, Q105变质 3 不工作 (F1故障) F1故障 高压开关坏, R205开路, D202, IC202失效 4 不工作 (F2故障) F2故障 外风机坏, R201开路, D201, IC201失效 5 不工作 (F3故障) F3故障 内风机坏, R209开路, D203, IC203失效 'KFR-75L/ WD3S KFR-120L/ WD3S' 1 不工作 (E2故障) E2故障 Q106, Q107, Q108, Q109, D115, D116, PC101失效 2 不工作 (E1故障) E1故障 Q103, Q104, D103失效 3 不工作 (F3故障) F3故障 R121, D107, PC102失效 'KFR-75W/ WD3S KFR-120W/ WDS' 1 外机不工作 不通电 ZNR201短路 (引起烧保险) 2 不工作 (F5故障) F5故障 R240, R241开路, D222, D201, IC205, IC211失效 3 不工作 (E2故障) E2故障 Q203, Q205, Q204, D210, D226, Q211失效 KFR-120L/ MAS 1 不工作 外机动作, 室内机不工作 D41, D42开路 2 不工作 (无内机通讯) E1故障 Q7, Q8失效 KFR-120W/ MAS 1 不工作 (P5故障) P5故障 R28, R31开路, D4, D5, PC5, PC6, Q7, Q8失效 2 不工作 (E4故障) E4故障 L1, Q10失效 'KFR-71LW/ M KFR-120LW/ MAS ( 三洋 ) ' 1 不工作 (P6故障, 显示异常或无通信) P6故障或无通讯或显示异常 S1, S2, S3, S4, S5, S6等开关位置错误或氧 化后接触不良 KFR-50W/ WBQ 1 不工作 (P4故障) P4故障 VD311, VD310, VD309, VD312失效 (其中一个或几个) 2 不通电 不通电 IC307, VD307短路, R321开路 'KFR-51 (71) L/ DFS (FS系列相同) ' 1 不工作 (不叫, 传感无温度, 不通电) 不叫, 无传感器温度, 不通电 D201失效 2 不工作 (不叫) 不叫 V201短路 3 显示异常 漏光 VD201短路 4 不工作 (E1故障) E1故障 V202短路, D201失效 'KFR-71L/ WDAS (12条也适合于KFR-50L/ WDCS) ' 1 不工作 (传感器温度异常) 传感器温度异常 CN301失效 2 不通电 不通电 D101失效, L101开路, F101开路 3 不工作 (F1故障) F1故障 E301失效, R310开路 4 不工作 (F2故障) F2故障 E302失效, R311开路 5 不工作 (F3故障) F3故障 E303失效, R315开路, XS306处零线炸开 KFR-28GW/ BC3 1 不制热 (冷) 且手动关机后运行灯闪 无通讯 D108, D109烧坏, VD501, D500, D501烧坏, R57开路, T01, D101模块失效 KFR-25 (28) (40) G/ BQ 1 不开机 不通电 R01, R02开路, IC01失效 2 不制热 (冷) 无通讯 C501失效 KFR-40 (+25) W/ BQ 1 不制热 (冷) 且灯闪 不通电 Q200, DB01, IC101失效, F01开路 2 不制热 (冷) 且灯闪 开机保护 IC203, IC204, IC205, IC207, IC200, IC201失效 3 不制热 (冷) 且灯闪 开机保护 C302, C308, C312缺损/ 开路, Q302, Q303, Q304, Q305, Q306, Q307参数异常 4 制热 (冷) 效果不好 电子膨胀阀切换异常 IC11开路, IC14开路 (副板) 'KFR-36GW/ BMF KFR-40GW/ BM' 1 运行灯闪且不开机 运行灯闪 E2PROM插座氧化 2 运行灯闪, 手动关机后1灯直亮 运行灯闪 PC10, PC11, IC14, T11失效, R42开路 3 运行灯闪, 手动关机后2灯直亮 运行灯闪 D29, C52, C59, C60, C61模块失效, PC13~PC18失效 KFR-32G/ DL 1 运行灯闪 长鸣 传感器电路异常 2 运行灯闪 制热后运行灯闪 CPU坏 KFR-30GW/ WDS 1 整机工作异常 (运行一会儿停机) 运行一会儿停机 D101失效 (+5V对地短路) 2 整机不工作 不启动 R109开路 (+24V, +12V, +5V正常) KFR-34GW/ WCS 1 遥控不开机 不遥控 C115参数失调 2 三灯闪且不开机 三灯闪 D107程序丢失 3 能遥控但不开机且手动不开机 手动不开机 S101失效 KFR-32GW/ A1 1 不通电 不通电 D105失效〈+12V偏低, 无+5V, D105发热〉 2 关机后压缩机不停 压缩机一直转 (D106第16脚一直处于低电平) D106失效 'KFR-32G/ DC2 (适用于DC2, DC3系列) ' 1 不通电 不通电 变压器开路 FS, DFS系列控制面板 1 不工作 (不叫) 不叫 V101, V102, V103, D101失效 2 显示异常 漏光 D103失效, C105失效 3 不工作 E1故障 V101, V103, D101失效 KFR-71L/ WDAS, KFR-50L/ WDCS, KFR-60L/ DXS, DA系列控制面板 1 不工作 (不叫) 不叫 V201, V202, V203失效及D101失效 2 不通电 不显示 C101短路, G301, D101失效 'KFR-75L/ WD3S KFR-120L/ WDS 控制面板' 1 按键全无作用 按键失效 K301开路或IC301失效, K301位置不正确 2 不工作 (不叫) 不叫 Q303, Q306, IC301失效 3 不通电 不通电 IC301, IC302, X301, D311, C312失效 KFR-71L/ D控制面板 1 不工作 (不叫) 不叫 Q302, Q303, Q304, Q305, IC301失效 2 无夜光 无夜光 Q307, RG301, R335, 背光源, IC301失效 'KFR-51L/ D (KFR-48L基本相同) ' 1 不工作 (不叫) 不叫 Q303, Q302, Q305, Q306, IC301失效 2 不通电 不通电 IC303, IC301, X301, IC302, C312, C318失效 长虹: 机型 代码 可能故障原因 F1 室内温度传感器异常 F2 室内盘管温度传感器异常 F3 室外环境温度传感器异常 KFR-45LW/ WDQ F4 室外盘管温度传感器异常 KFR-45LW/ WBQ F5 压缩机排气温度传感器异常 KFR-50LW/ WBQ P1 压缩机排气温度传感器异常 P2 CT电流异常 P4 JPM故障保护 P5 四通阀切换异常 E1 室内主控板与控制面板之间通讯异常 E2 室内主控板与室外控制板之间通讯异常 E1 主控板与面板之间通讯错误 E2 主控板与室外板之间通讯错误 F1 高压开关保护 F2 室外风扇电机热保护器动作 KF-75LW/ WDS F3 室内风扇电机热保护器动作 KF-75W/ W3S F4 低压开关保护 KFR-75LW/ WDES F5 逆相保护 KFR-120LW/ WDS F6 缺相保护 KF-120LW/ WS H1 压缩机过电流保护 H2 压缩机堵转保护 H3 检测不到压缩机电流 P1 制冷过载保护 P2 制热过载保护 P3 系统异常保护 P4 自动模式下室内温度传感器异常 无显示 制冷剂不足 E1 控制面板测到从室内机传来的异常信息 E2 控制面板测到从室内机传来的异常信息 E3 室内机测到从控制面板传来的异常信息 E4 室内机测到从室外机传来的异常信息 E5 室内机测到从室外机传来的异常信息 E6 室外机测到从室内机传来的异常信息 E7 室外机测到从室内机传来的异常信息 P1 室内风扇电机热保护器动作 P2 室外风扇电机与压缩机热保护器动作 KFR-120LW/ M P3 排气温度异常 KFR-120LW/ MAS P4 高压开关动作 KFR-71LW/ M P5 逆相保护 (对KFR-71LW/ M是主控板上开关位置设置错误) P6 室内机与室外机的模式不兼? F1 室内机热敏电阻断路或者受损 F2 室内机热敏电阻断路或者受损 F4 室外机热敏电阻断路或者受损 F5 室外机热敏电阻断路或者受损 F6 室外机热敏电阻断路或者受损 F7 室外机热敏电阻断路或者受损 F8 室外机热敏电阻断路或者受损 H1 压缩机电机过流 H2 压缩机电机堵转 H3 压缩机电流检测异常 H6 低压开关动作 H7 连接室内机和室外机线路或管道接错 E1 通讯异常 48LW P1 制冷过载 60系列 P2 制热过载 51系列 P3 系统异常保护 P4 自动模式下室内温度传感器异常 KFR-7ILW/ D E1 通信异常 KFR-71LW/ WD P1 制冷过载 KF-71LW P2 制热过载 P3 系统异常保护 P4 自动模式室内温度传感器异常 F1 高压开关保护 (序号线接错或断裂, 控制板上光藕或R205损坏) F2 室外风扇电机热保护 (热保护器坏, 控制板上光藕或R205损坏) F3 室内风扇电机热保护 (热保护器坏, 控制板上光藕或R205损坏) KFR-50LWWDFB E1 通信异常 KF-50LWWDF P1 制冷过载 KF-60LWWDF P2 制热过载 KF-71LWWDF F1 高压开关保护 KFR-51LWWDFB F2 室外风扇电机热保护 KFR-60LWWDFB F3 室内风扇电机热保护 F7 温度传感器损坏或异常 F8 系统保护异常 机型 代码 可能故障原因 F1 室内温度传感器异常 F2 室内盘管温度传感器异常 F3 室外环境温度传感器异常 KFR-45LW/ WDQ F4 室外盘管温度传感器异常 KFR-45LW/ WBQ F5 压缩机排气温度传感器异常 KFR-50LW/ WBQ P1 压缩机排气温度传感器异常 P2 CT电流异常 P4 JPM故障保护 P5 四通阀切换异常 E1 室内主控板与控制面板之间通讯异常 E2 室内主控板与室外控制板之间通讯异常 E1 主控板与面板之间通讯错误 E2 主控板与室外板之间通讯错误 F1 高压开关保护 F2 室外风扇电机热保护器动作 KF-75LW/ WDS F3 室内风扇电机热保护器动作 KF-75W/ W3S F4 低压开关保护 KFR-75LW/ WDES F5 逆相保护 KFR-120LW/ WDS F6 缺相保护 KF-120LW/ WS H1 压缩机过电流保护 H2 压缩机堵转保护 H3 检测不到压缩机电流 P1 制冷过载保护 P2 制热过载保护 P3 系统异常保护 P4 自动模式下室内温度传感器异常 无显示 制冷剂不足 E1 控制面板测到从室内机传来的异常信息 E2 控制面板测到从室内机传来的异常信息 E3 室内机测到从控制面板传来的异常信息 E4 室内机测到从室外机传来的异常信息 E5 室内机测到从室外机传来的异常信息 E6 室外机测到从室内机传来的异常信息 E7 室外机测到从室内机传来的异常信息 P1 室内风扇电机热保护器动作 P2 室外风扇电机与压缩机热保护器动作 KFR-120LW/ M P3 排气温度异常 KFR-120LW/ MAS P4 高压开关动作 KFR-71LW/ M P5 逆相保护 (对KFR-71LW/ M是主控板上开关位置设置错误) P6 室内机与室外机的模式不兼? F1 室内机热敏电阻断路或者受损 F2 室内机热敏电阻断路或者受损 F4 室外机热敏电阻断路或者受损 F5 室外机热敏电阻断路或者受损 F6 室外机热敏电阻断路或者受损 F7 室外机热敏电阻断路或者受损 F8 室外机热敏电阻断路或者受损 H1 压缩机电机过流 H2 压缩机电机堵转 H3 压缩机电流检测异常 H6 低压开关动作 H7 连接室内机和室外机线路或管道接错 E1 通讯异常 48LW P1 制冷过载 60系列 P2 制热过载 51系列 P3 系统异常保护 P4 自动模式下室内温度传感器异常 KFR-7ILW/ D E1 通信异常 KFR-71LW/ WD P1 制冷过载 KF-71LW P2 制热过载 P3 系统异常保护 P4 自动模式室内温度传感器异常 F1 高压开关保护 (序号线接错或断裂, 控制板上光藕或R205损坏) F2 室外风扇电机热保护 (热保护器坏, 控制板上光藕或R205损坏) F3 室内风扇电机热保护 (热保护器坏, 控制板上光藕或R205损坏) KFR-50LWWDFB E1 通信异常 KF-50LWWDF P1 制冷过载 KF-60LWWDF P2 制热过载 KF-71LWWDF F1 高压开关保护 KFR-51LWWDFB F2 室外风扇电机热保护 KFR-60LWWDFB F3 室内风扇电机热保护 F7 温度传感器损坏或异常 F8 系统保护异常 机型 序号 整机故障现象 印制板故障现象 故障位号 'KFR-36GW/ D (KFR-35GW/ WDS与其基本相同) ' 1 不通电 不通电 D1-D4, D5, D6, D9短路, IC6短路, 保险管开路 2 无风 电机不转 DC10变质 3 无风 电机抖动, 无+8.2V 调节R28 4 压缩机工作一会停机 无压缩机CT电流 CT1开路 大清快EQ系列 1 不通电 (通电指示灯不亮) 不通电 C1, C4, C19变质, T1, R4, R60开路, VDZ2, D3, VD4, VD6, VD3, VD2, VD16, VD17, VC1短路 2 无风 遥控大电机不转 VD1, VD15, D6, V3, R10失效 3 工作一会停机, 指示灯闪 工作一会电机停, 指示灯闪 V2变质 4 不工作 不通电 (无晶振电压) C10, C11变质 'KFR-28GW/ BP模块 (KFR-28GW/ BMF同) ' 1 室外压缩机不启动 压机不动 模块短路或参数失调及开路 2 外机不工作 外机不通电 E2失效, BT1, R2开路, Z1短路 'KFR-28G/ BP (KFR-28G/ BMF同) 室内主板' 1 不停机 通电室内电机就转 C503, IC203失效 2 不通电 不通电 F504, RL401失效 3 室内机不工作 电机不转 DQ201失效 KFR-28W/ BMF 1 室外机不工作 不通电 F101, F102, RT201开路, K505失效 2 室外压缩机不工作 压缩机不启动 D303, D301失效, R504, R509开路, D403, T202失效 3 外机不工作 (无通讯) 外机不动 L102, C207, C205, D400, D402失效, D303失效 KFR-28W/ BP 1 室外风扇不转 风机不转 C501变质, RL502, RL503, IC401失效 2 外机不通电 不通电 FUSE101, FUSE102, PTC501开路 3 室外压缩机不工作 压缩机不动 R504, R509, BT202, PC401失效 4 不工作 (无通讯) 无通讯 PC400, PC402失效, R502开路 5 工作一会停机 压缩机启动一会就停 BT202, C207, C205失效 KFR-60L/ WDES 1 不工作 E1故障 V104, V105变质或虚焊 KFR-71L/ WDS 1 不通电 不通电 IC102, IC103失效, L102, D122开路 2 不工作 不叫 (E1故障) Q104, Q105变质 3 不工作 (F1故障) F1故障 高压开关坏, R205开路, D202, IC202失效 4 不工作 (F2故障) F2故障 外风机坏, R201开路, D201, IC201失效 5 不工作 (F3故障) F3故障 内风机坏, R209开路, D203, IC203失效 'KFR-75L/ WD3S KFR-120L/ WD3S' 1 不工作 (E2故障) E2故障 Q106, Q107, Q108, Q109, D115, D116, PC101失效 2 不工作 (E1故障) E1故障 Q103, Q104, D103失效 3 不工作 (F3故障) F3故障 R121, D107, PC102失效 'KFR-75W/ WD3S KFR-120W/ WDS' 1 外机不工作 不通电 ZNR201短路 (引起烧保险) 2 不工作 (F5故障) F5故障 R240, R241开路, D222, D201, IC205, IC211失效 3 不工作 (E2故障) E2故障 Q203, Q205, Q204, D210, D226, Q211失效 KFR-120L/ MAS 1 不工作 外机动作, 室内机不工作 D41, D42开路 2 不工作 (无内机通讯) E1故障 Q7, Q8失效 KFR-120W/ MAS 1 不工作 (P5故障) P5故障 R28, R31开路, D4, D5, PC5, PC6, Q7, Q8失效 2 不工作 (E4故障) E4故障 L1, Q10失效 'KFR-71LW/ M KFR-120LW/ MAS (三洋) ' 1 不工作 (P6故障, 显示异常或无通信) P6故障或无通讯或显示异常 S1, S2, S3, S4, S5, S6等开关位置错误或氧化后接触不良 KFR-50W/ WBQ 1 不工作 (P4故障) P4故障 VD311, VD310, VD309, VD312失效 (其中一个或几个) 2 不通电 不通电 IC307, VD307短路, R321开路 'KFR-51 (71) L/ DFS (FS系列相同) ' 1 不工作 (不叫, 传感无温度, 不通电) 不叫, 无传感器温度, 不通电 D201失效 2 不工作 (不叫) 不叫 V201短路 3 显示异常 漏光 VD201短路 4 不工作 (E1故障) E1故障 V202短路, D201失效 'KFR-71L/ WDAS (12条也适合于KFR-50L/ WDCS) ' 1 不工作 (传感器温度异常) 传感器温度异常 CN301失效 2 不通电 不通电 D101失效, L101开路, F101开路 3 不工作 (F1故障) F1故障 E301失效, R310开路 4 不工作 (F2故障) F2故障 E302失效, R311开路 5 不工作 (F3故障) F3故障 E303失效, R315开路, XS306处零线炸开 KFR-28GW/ BC3 1 不制热 (冷) 且手动关机后运行灯闪 无通讯 D108, D109烧坏, VD501, D500, D501烧坏, R57开路, T01, D101模块失效 KFR-25 (28) (40) G/ BQ 1 不开机 不通电 R01, R02开路, IC01失效 2 不制热 (冷) 无通讯 C501失效 KFR-40 (+25) W/ BQ 1 不制热 (冷) 且灯闪 不通电 Q200, DB01, IC101失效, F01开路 2 不制热 (冷) 且灯闪 开机保护 IC203, IC204, IC205, IC207, IC200, IC201失效 3 不制热 (冷) 且灯闪 开机保护 C302, C308, C312缺损/ 开路, Q302, Q303, Q304, Q305, Q306, Q307参数异常 4 制热 (冷) 效果不好 电子膨胀阀切换异常 IC11开路, IC14开路 (副板) 'KFR-36GW/ BMF KFR-40GW/ BM' 1 运行灯闪且不开机 运行灯闪 E2PROM插座氧化 2 运行灯闪, 手动关机后1灯直亮 运行灯闪 PC10, PC11, IC14, T11失效, R42开路 3 运行灯闪, 手动关机后2灯直亮 运行灯闪 D29, C52, C59, C60, C61模块失效, PC13~PC18失效 KFR-32G/ DL 1 运行灯闪 长鸣 传感器电路异常 2 运行灯闪 制热后运行灯闪 CPU坏 KFR-30GW/ WDS 1 整机工作异常 (运行一会儿停机) 运行一会儿停机 D101失效 (+5V对地短路) 2 整机不工作 不启动 R109开路 (+24V, +12V, +5V正常) KFR-34GW/ WCS 1 遥控不开机 不遥控 C115参数失调 2 三灯闪且不开机 三灯闪 D107程序丢失 3 能遥控但不开机且手动不开机 手动不开机 S101失效 KFR-32GW/ A1 1 不通电 不通电 D105失效〈+12V偏低, 无+5V, D105发热〉 2 关机后压缩机不停 压缩机一直转 (D106第16脚一直处于低电平) D106失效 'KFR-32G/ DC2 (适用于DC2, DC3系列) ' 1 不通电 不通电 变压器开路 FS, DFS系列控制面板 1 不工作 (不叫) 不叫 V101, V102, V103, D101失效 2 显示异常 漏光 D103失效, C105失效 3 不工作 E1故障 V101, V103, D101失效 KFR-71L/ WDAS, KFR-50L/ WDCS, KFR-60L/ DXS, DA系列控制面板 1 不工作 (不叫) 不叫 V201, V202, V203失效及D101失效 2 不通电 不显示 C101短路, G301, D101失效 'KFR-75L/ WD3S KFR-120L/ WDS 控制面板' 1 按键全无作用 按键失效 K301开路或IC301失效, K301位置不正确 2 不工作 (不叫) 不叫 Q303, Q306, IC301失效 3 不通电 不通电 IC301, IC302, X301, D311, C312失效 KFR-71L/ D控制面板 1 不工作 (不叫) 不叫 Q302, Q303, Q304, Q305, IC301失效 2 无夜光 无夜光 Q307, RG301, R335, 背光源, IC301失效 'KFR-51L/ D (KFR-48L基本相同) ' 1 不工作 (不叫) 不叫 Q303, Q302, Q305, Q306, IC301失效 2 不通电 不通电 IC303, IC301, X301, IC302, C312, C318失效 机型 代码 可能故障原因 F1 室内温度传感器异常 F2 室内盘管温度传感器异常 F3 室外环境温度传感器异常 KFR-45LW/ WDQ F4 室外盘管温度传感器异常 KFR-45LW/ WBQ F5 压缩机排气温度传感器异常 KFR-50LW/ WBQ P1 压缩机排气温度传感器异常 P2 CT电流异常 P4 JPM故障保护 P5 四通阀切换异常 E1 室内主控板与控制面板之间通讯异常 E2 室内主控板与室外控制板之间通讯异常 E1 主控板与面板之间通讯错误 E2 主控板与室外板之间通讯错误 F1 高压开关保护 F2 室外风扇电机热保护器动作 KF-75LW/ WDS F3 室内风扇电机热保护器动作 KF-75W/ W3S F4 低压开关保护 KFR-75LW/ WDES F5 逆相保护 KFR-120LW/ WDS F6 缺相保护 KF-120LW/ WS H1 压缩机过电流保护 H2 压缩机堵转保护 H3 检测不到压缩机电流 P1 制冷过载保护 P2 制热过载保护 P3 系统异常保护 P4 自动模式下室内温度传感器异常 无显示 制冷剂不足 E1 控制面板测到从室内机传来的异常信息 E2 控制面板测到从室内机传来的异常信息 E3 室内机测到从控制面板传来的异常信息 E4 室内机测到从室外机传来的异常信息 E5 室内机测到从室外机传来的异常信息 E6 室外机测到从室内机传来的异常信息 E7 室外机测到从室内机传来的异常信息 P1 室内风扇电机热保护器动作 P2 室外风扇电机与压缩机热保护器动作 KFR-120LW/ M P3 排气温度异常 KFR-120LW/ MAS P4 高压开关动作 KFR-71LW/ M P5 逆相保护 (对KFR-71LW/ M是主控板上开关位置设置错误) P6 室内机与室外机的模式不兼? F1 室内机热敏电阻断路或者受损 F2 室内机热敏电阻断路或者受损 F4 室外机热敏电阻断路或者受损 F5 室外机热敏电阻断路或者受损 F6 室外机热敏电阻断路或者受损 F7 室外机热敏电阻断路或者受损 F8 室外机热敏电阻断路或者受损 H1 压缩机电机过流 H2 压缩机电机堵转 H3 压缩机电流检测异常 H6 低压开关动作 H7 连接室内机和室外机线路或管道接错 E1 通讯异常 48LW P1 制冷过载 60系列 P2 制热过载 51系列 P3 系统异常保护 P4 自动模式下室内温度传感器异常 KFR-7ILW/ D E1 通信异常 KFR-71LW/ WD P1 制冷过载 KF-71LW P2 制热过载 P3 系统异常保护 P4 自动模式室内温度传感器异常 F1 高压开关保护 (序号线接错或断裂, 控制板上光藕或R205损坏) F2 室外风扇电机热保护 (热保护器坏, 控制板上光藕或R205损坏) F3 室内风扇电机热保护 (热保护器坏, 控制板上光藕或R205损坏) KFR-50LWWDFB E1 通信异常 KF-50LWWDF P1 制冷过载 KF-60LWWDF P2 制热过载 KF-71LWWDF F1 高压开关保护 KFR-51LWWDFB F2 室外风扇电机热保护 KFR-60LWWDFB F3 室内风扇电机热保护 F7 温度传感器损坏或异常 F8 系统保护异常 机型 序号 整机故障现象 印制板故障现象 故障位号 'KFR-36GW/ D (KFR-35GW/ WDS与其基本相同) ' 1 不通电 不通电 D1-D4, D5, D6, D9短路, IC6短路, 保险管开路 2 无风 电机不转 DC10变质 3 无风 电机抖动, 无+8.2V 调节R28 4 压缩机工作一会停机 无压缩机CT电流 CT1开路 大清快EQ系列 1 不通电 (通电指示灯不亮) 不通电 C1, C4, C19变质, T1, R4, R60开路, VDZ2, D3, VD4, VD6, VD3, VD2, VD16, VD17, VC1短路 2 无风 遥控大电机不转 VD1, VD15, D6, V3, R10失效 3 工作一会停机, 指示灯闪 工作一会电机停, 指示灯闪 V2变质 4 不工作 不通电 (无晶振电压) C10, C11变质 'KFR-28GW/ BP模块 (KFR-28GW/ BMF同) ' 1 室外压缩机不启动 压机不动 模块短路或参数失调及开路 2 外机不工作 外机不通电 E2失效, BT1, R2开路, Z1短路 'KFR-28G/ BP (KFR-28G/ BMF同) 室内主板' 1 不停机 通电室内电机就转 C503, IC203失效 2 不通电 不通电 F504, RL401失效 3 室内机不工作 电机不转 DQ201失效 KFR-28W/ BMF 1 室外机不工作 不通电 F101, F102, RT201开路, K505失效 2 室外压缩机不工作 压缩机不启动 D303, D301失效, R504, R509开路, D403, T202失效 3 外机不工作 (无通讯) 外机不动 L102, C207, C205, D400, D402失效, D303失效 KFR-28W/ BP 1 室外风扇不转 风机不转 C501变质, RL502, RL503, IC401失效 2 外机不通电 不通电 FUSE101, FUSE102, PTC501开路 3 室外压缩机不工作 压缩机不动 R504, R509, BT202, PC401失效 4 不工作 (无通讯) 无通讯 PC400, PC402失效, R502开路 5 工作一会停机 压缩机启动一会就停 BT202, C207, C205失效 KFR-60L/ WDES 1 不工作 E1故障 V104, V105变质或虚焊 KFR-71L/ WDS 1 不通电 不通电 IC102, IC103失效, L102, D122开路 2 不工作 不叫 (E1故障) Q104, Q105变质 3 不工作 (F1故障) F1故障 高压开关坏, R205开路, D202, IC202失效 4 不工作 (F2故障) F2故障 外风机坏, R201开路, D201, IC201失效 5 不工作 (F3故障) F3故障 内风机坏, R209开路, D203, IC203失效 'KFR-75L/ WD3S KFR-120L/ WD3S' 1 不工作 (E2故障) E2故障 Q106, Q107, Q108, Q109, D115, D116, PC101失效 2 不工作 (E1故障) E1故障 Q103, Q104, D103失效 3 不工作 (F3故障) F3故障 R121, D107, PC102失效 'KFR-75W/ WD3S KFR-120W/ WDS' 1 外机不工作 不通电 ZNR201短路 (引起烧保险) 2 不工作 (F5故障) F5故障 R240, R241开路, D222, D201, IC205, IC211失效 3 不工作 (E2故障) E2故障 Q203, Q205, Q204, D210, D226, Q211失效 KFR-120L/ MAS 1 不工作 外机动作, 室内机不工作 D41, D42开路 2 不工作 (无内机通讯) E1故障 Q7, Q8失效 KFR-120W/ MAS 1 不工作 (P5故障) P5故障 R28, R31开路, D4, D5, PC5, PC6, Q7, Q8失效 2 不工作 (E4故障) E4故障 L1, Q10失效 'KFR-71LW/ M KFR-120LW/ MAS (三洋) ' 1 不工作 (P6故障, 显示异常或无通信) P6故障或无通讯或显示异常 S1, S2, S3, S4, S5, S6等开关位置错误或氧化后接触不良 KFR-50W/ WBQ 1 不工作 (P4故障) P4故障 VD311, VD310, VD309, VD312失效 (其中一个或几个) 2 不通电 不通电 IC307, VD307短路, R321开路 'KFR-51 (71) L/ DFS (FS系列相同) ' 1 不工作 (不叫, 传感无温度, 不通电) 不叫, 无传感器温度, 不通电 D201失效 2 不工作 (不叫) 不叫 V201短路 3 显示异常 漏光 VD201短路 4 不工作 (E1故障) E1故障 V202短路, D201失效 'KFR-71L/ WDAS (12条也适合于KFR-50L/ WDCS) ' 1 不工作 (传感器温度异常) 传感器温度异常 CN301失效 2 不通电 不通电 D101失效, L101开路, F101开路 3 不工作 (F1故障) F1故障 E301失效, R310开路 4 不工作 (F2故障) F2故障 E302失效, R311开路 5 不工作 (F3故障) F3故障 E303失效, R315开路, XS306处零线炸开 KFR-28GW/ BC3 1 不制热 (冷) 且手动关机后运行灯闪 无通讯 D108, D109烧坏, VD501, D500, D501烧坏, R57开路, T01, D101模块失效 KFR-25 (28) (40) G/ BQ 1 不开机 不通电 R01, R02开路, IC01失效 2 不制热 (冷) 无通讯 C501失效 KFR-40 (+25) W/ BQ 1 不制热 (冷) 且灯闪 不通电 Q200, DB01, IC101失效, F01开路 2 不制热 (冷) 且灯闪 开机保护 IC203, IC204, IC205, IC207, IC200, IC201失效 3 不制热 (冷) 且灯闪 开机保护 C302, C308, C312缺损/ 开路, Q302, Q303, Q304, Q305, Q306, Q307参数异常 4 制热 (冷) 效果不好 电子膨胀阀切换异常 IC11开路, IC14开路 (副板) 'KFR-36GW/ BMF KFR-40GW/ BM' 1 运行灯闪且不开机 运行灯闪 E2PROM插座氧化 2 运行灯闪, 手动关机后1灯直亮 运行灯闪 PC10, PC11, IC14, T11失效, R42开路 3 运行灯闪, 手动关机后2灯直亮 运行灯闪 D29, C52, C59, C60, C61模块失效, PC13~PC18失效 KFR-32G/ DL 1 运行灯闪 长鸣 传感器电路异常 2 运行灯闪 制热后运行灯闪 CPU坏 KFR-30GW/ WDS 1 整机工作异常 (运行一会儿停机) 运行一会儿停机 D101失效 (+5V对地短路) 2 整机不工作 不启动 R109开路 (+24V, +12V, +5V正常) KFR-34GW/ WCS 1 遥控不开机 不遥控 C115参数失调 2 三灯闪且不开机 三灯闪 D107程序丢失 3 能遥控但不开机且手动不开机 手动不开机 S101失效 KFR-32GW/ A1 1 不通电 不通电 D105失效〈+12V偏低, 无+5V, D105发热〉 2 关机后压缩机不停 压缩机一直转 (D106第16脚一直处于低电平) D106失效 'KFR-32G/ DC2 (适用于DC2, DC3系列) ' 1 不通电 不通电 变压器开路 FS, DFS系列控制面板 1 不工作 (不叫) 不叫 V101, V102, V103, D101失效 2 显示异常 漏光 D103失效, C105失效 3 不工作 E1故障 V101, V103, D101失效 KFR-71L/ WDAS, KFR-50L/ WDCS, KFR-60L/ DXS, DA系列控制面板 1 不工作 (不叫) 不叫 V201, V202, V203失效及D101失效 2 不通电 不显示 C101短路, G301, D101失效 'KFR-75L/ WD3S KFR-120L/ WDS 控制面板' 1 按键全无作用 按键失效 K301开路或IC301失效, K301位置不正确 2 不工作 (不叫) 不叫 Q303, Q306, IC301失效 3 不通电 不通电 IC301, IC302, X301, D311, C312失效 KFR-71L/ D控制面板 1 不工作 (不叫) 不叫 Q302, Q303, Q304, Q305, IC301失效 2 无夜光 无夜光 Q307, RG301, R335, 背光源, IC301失效 'KFR-51L/ D (KFR-48L基本相同) ' 1 不工作 (不叫) 不叫 Q303, Q302, Q305, Q306, IC301失效 2 不通E1-----E7串行通信信号传送接收错误. P1------内风机热保护 P2------外风机压机热保护 P3------排气温度异常 P4------高压保护 P5------逆相保护 P6------内外机模式不兼容 F1------E1=RT2 F2------E2=RT3 F4------RT8 F5------RT4 F6------C1=RT6 F7------C2=RT7 F8------RT5 H1------压机过载 H2------压机堵转 H3------压机电流异常 H6------低压保护 H7------内外机线路或管道接错电 不通电 IC303, IC301, X301, IC302, C312, C318失效 机型 代码 可能故障原因 F1 室内温度传感器异常 F2 室内盘管温度传感器异常 F3 室外环境温度传感器异常 KFR-45LW/ WDQ F4 室外盘管温度传感器异常 KFR-45LW/ WBQ F5 压缩机排气温度传感器异常 KFR-50LW/ WBQ P1 压缩机排气温度传感器异常 P2 CT电流异常 P4 JPM故障保护 P5 四通阀切换异常 E1 室内主控板与控制面板之间通讯异常 E2 室内主控板与室外控制板之间通讯异常 E1 主控板与面板之间通讯错误 E2 主控板与室外板之间通讯错误 F1 高压开关保护 F2 室外风扇电机热保护器动作 KF-75LW/ WDS F3 室内风扇电机热保护器动作 KF-75W/ W3S F4 低压开关保护 KFR-75LW/ WDES F5 逆相保护 KFR-120LW/ WDS F6 缺相保护 KF-120LW/ WS H1 压缩机过电流保护 H2 压缩机堵转保护 H3 检测不到压缩机电流 P1 制冷过载保护 P2 制热过载保护 P3 系统异常保护 KFR-28W/ BC3 (G2861C3) 插入电源插头运行灯以2HZ的频率闪烁, 则室内主板上24C02 (EEPROM) 数据不良等或IC插座接触不良或忘记安装. 指示灯 符号说明√灯亮*灯闪╳灯灭 H83 空清 H82 待机 H81 定时 H80 运转 诊断内容 故障内容 ╳ ╳ ╳ √ 串行通讯异常 机组间配线错误, 接触不良, 电源线AC220/ DC310接触不良 ╳ ╳ √ ╳ 功率驱动过负荷保护 功率驱动不良压机锁住, 磨损严重, 室外主板不良, 外风机不转 ╳ √ ╳ √ 室内盘管温度异常 传感器开路或短路 ╳ √ √ ╳ 室内温度传感器异常 传感器开路或短路 ╳ √ √ √ 压机温度传感器异常 传感器开路或短路XS601 √ ╳ ╳ ╳ 室外盘管温度异常 传感器开路或短路XS600 √ ╳ ╳ √ 室外环境温度异常 传感器开路或短路XS602 √ ╳ √ ╳ 压机排气温度过高保护 制冷剂不足, 毛细管堵塞, 压机温度传感器不良, 制冷外风机停转 √ ╳ √ √ 室内盘管温度过高保护 制热时室内盘管温度过高 √ √ ╳ ╳ 低温保护 室外环境温度低于-17℃ √ √ ╳ √ 电流过低 压机工作时, 电流过低 √ √ √ ╳ 电流过高 压机工作时或停机, 电流太高 √ √ √ √ AC输入电压异常 过电压, 欠电压保护动作 ╳ ╳ * ╳ 压机顶盖热保护开关断开 缺氟等 ╳ ╳ * * 室外盘管温度过热保护 制冷时, 外盘等压力保护 ╳ * ╳ ╳ 室内盘管冻结保护 制冷时, 内盘管温度太低 ╳ * * ╳ 四通阀切换异常 ╳ * * * 室外EEPROM异常 EEPROM数据不良, IC插座接触不良 H3: 检测不到压缩机电流 P3 系统异常保护
志高 空调 故障代码
第一部分: 家用空调部分故障代码 一, 志高 285325388418挂壁式空调故障代码表: 包括: 0304050607080910111213354041款 故障内容 运行灯LED1 运行灯 定时灯 室内盘管温度传感器故障 闪亮1次/ 8秒 点亮 室内温度传感器故障 闪亮2次/ 8秒 点亮 室外机组异常故障 点亮 闪亮5次/ 8秒 室内风机故障 闪亮6次/ 8秒 点亮 闪亮一次为亮0.5秒, 灭0.5秒. 待机状态下才检测, 显示室内盘管传感器故障, 室内温度传感器故障. 若室内风机运行时, 连续30秒钟无反馈信号, 则关闭空调器并显示室内风机故障. 二, 志高晶彩系列挂壁式空调故障代码: 包括: 02款, 16181920款 故障内容 数码管显示代码 说明 室内温度传感器故障 L2 开/ 关机状态均显示, 若同时故障, 则显示代码L1, 修复后立即回显室温 室内盘管温度传感器故障 L1 室内风机故障 L6 室内风机运行时, 连续30秒无反馈信号, 则关机并显示L6. 室外机组异常故障 E5 关机显示'E5'后, 设定温度有效, 但数码管无显示, 用'应急'或遥控'开/ 关'键可重新开机, 数码管回显室温. 三, '天'系列, 小康系列挂机 (51和51以下) 机型故障代码 包括: 25款, 26424345464748505152款 故障内容 数码管显示状态 室内盘管传感器故障 E3 2志高空调故障代码 室内温度传感器故障 E2 室外机组异常 E4 室内风机故障 E5 化霜 DF 四, 志高18NV/ 24NV空调 (5100-6600W) : 包括: 17款, 343637款 故 障 内 容 运行灯LED1 说 明 室温传感器 闪亮2次/ 4秒 关机时显示 盘管传感器 闪亮3次/ 5秒 关机时显示 室外机异常 闪亮4次/ 6秒 开关机时显示 无风机反馈 (PG专用) 闪亮5次/ 7秒 关机时显示 无交流零点检测信号 (PG专用) 闪亮6次/ 8秒 关机时显示 闪亮一次为: 亮0.5秒, 灭0.5秒. 如闪亮2次/ 4秒为: 亮0.5秒, 灭0.5秒 , 亮0.5秒, 灭0.5秒 ,停2秒, 一个周期共4秒, 如此循环. 对于非变频机, 以下有关灯闪烁的解释不再重复. 注: 无风机反馈, 无交流零点检测信号都属于室内风机故障. 五, LED显示型柜机操作板自检代码表: 包括: 05款, 060708款 自检信息 自检代码 说明 室外机组异常 12-29 1--18 室外机组故障 室温传感器故障 11-28 1--18 热敏电阻发生故障 室内盘管传感器故障 10-27 1--18 热敏电阻发生故障 外反馈故障 8-25 1--18 过流, 电网异常 3, 志高空调故障代码 过热保护 结霜保护 7-24 1--18 风路短路循环, 内风机有故障, 空气过滤网堵塞 注: 柜机自检代码的显示用 (1-18) 灯常亮, 加上其它灯来表达自检信息. 六, 志高2HP华丽柜式空调, 华丽VFD柜机故障代码表: 包括: 02款, 040910款 故障内容 数码管显示代码 说明 室温传感器故障 11 液晶片显示'故障'及房间温度处显示故障代码 管温传感器故障 10 制热内盘管过热保护 7 制冷内盘管结霜保护 7 室外机组异常 12 电源异常或过流保护 13 七, 数码管型柜机故障代码 (11款, 17182022款) 自检内容 多彩屏中间双8数码管显示代码 室内管温传感器故障 E3 室内室温传感器故障 E2 室外机组异常 E4 结霜保护 E8 过热保护 E8 过流或相序保护 E7 八, 变频一拖一挂机, 柜机故障显示一览表 一挂机故障显示表 内/ 外机故障 故障指示 故障内容 1. 室内故障 1, 志高空调故障代码 定时灯常亮 / 运行灯闪亮 1次/ 8秒 室内盘管传感器异常 2次/ 8秒 室内环境温度传感器异常 6次/ 8秒 风扇电机异常 2, 室外异常 运行灯连续闪亮 / 睡眠灯闪亮 1次/ 8秒 室外环境温度传感器异常 2次/ 8秒 室外盘管传感器异常 4次/ 8秒 排气温度传感器异常 运行灯常亮 / 睡眠灯闪亮 7次/ 8秒 模块保护 3次/ 8秒 压机过流保护 5次/ 8秒 冷媒不足, 压机过热保护 6次/ 8秒 通讯故障 二柜机 故障内容 (黄灯) 故障指示灯闪烁次数 模块故障 闪1次 通讯故障 闪2次 保留 闪3次 缺氟保护或四通阀故障 闪4次 压缩机过流 闪5次 压缩机排气温度过高 闪6次 外主板温度传感器故障或温度过高 () 65℃) 闪7次 压缩机排气温度传感器故障 闪8次 室外盘管中点传感器故障 闪9次 5, 志高空调故障代码 室外环境传感器故障 闪11次 室外主板软件复位 闪12次 故障指示灯闪烁频率为1Hz (即间隔为1秒) ,每种故障至少闪烁显示30秒. 液晶显示故障为Fn, n对应上表闪烁次数, 如F2表示通讯故障. 三变频一拖一柜机 (指示灯显示款) 故障代码 2004-8-10 故障显示 故障内容 12-29灯亮 通讯故障 11-28灯亮 室内温度传感器故障 10-27灯亮 室内盘管温度传感器故障 9-26灯亮 室内盘管温度过热保护 8-25灯亮 缺氟保护 7-24灯亮 模块保护 6-23灯亮 系统过流保护或空载过流故障 5-22灯亮 压机排气过热故障 4-21灯亮 室外看门狗复位故障 3-20灯亮 室外传感器故障 1-18灯亮 保护状态 四, KFR-51LW/ BP 1) 室内机显示故障 No LCD 故 障 内 容 1 F1 通讯故障 2 F3 室内房间温度传感器异常 3 F6 室内盘管温度传感器异常 4 无显示 通讯电源故障 2) 室外机 显示故障 No LCD 故 障 内 容 6, 志高空调故障代码 1 E1 IPM模块故障 2 E2 压缩机电流过高 3 E3 压缩机温度过高 4 E4 室外温度传感器异常 5 无显示 通讯电源故障 第二部分: 商用空调故障代码 一. 四灯天花空调机故障代码表 自检信息 发光管自检代码 说明 除霜提示 闪烁1次/ 1秒 开机显示 (运行灯) 防冷风提示 闪烁1次/ 3秒 开机显示 (运行灯) 室温传感器故障 运行灯闪烁2次/ 4秒 关机显示, 保护灯常亮 管温传感器故障 运行灯闪烁3次/ 5秒 关机显示, 保护灯常亮 室外机异常 运行灯闪烁4次/ 6秒 关机显示, 保护灯常亮 室内蒸发器结霜保护 运行灯闪烁5次/ 7秒 关机显示, 保护灯常亮 外反馈故障 运行灯闪烁7次/ 9秒 关机显示, 保护灯常亮 过热保护 运行灯闪烁8次/ 10秒 关机显示, 保护灯常亮 水泵故障 运行灯闪烁9次/ 11秒 关机显示, 保护灯常亮 二, 两灯天花机故障代码表 红灯闪烁情况 故障意义 7, 志高空调故障代码 2次/ 4秒 盘管故障 3次/ 5秒 室温故障 4次/ 6秒 水泵故障 5次/ 7秒 室外故障 6次/ 8秒 防结霜保护 7次/ 9秒 室外机组 (过流, 电网电压异常) 8次/ 10秒 过热保护 三, 风管机, 风机盘管, 洁净空调液晶屏显示故障代码表 故障内容 LCD显示内容 室内房间温度传感器故障 E2 室内盘管温度传感器故障 E3 低压保护 E4 结霜保护 E8 过流或相序保护 E7 过热保护 E8 系统 控制 主板通讯故障 E1 室外机异常保护 E9
奥克斯 空调 故障代码 不分机组型号 E1室温传感器 E2室外管温传感器 E3室内管温 E4内外通讯, PG转速异常 E5压缩机过载, 低压保护 E6三相保护 E7室外过流 E8压缩机排气传感器 E9压缩机排气温度 奥克斯故障代码: H (除KFR-25G/ H) ,H1, HA, HB, HY系列 (定时灯) 故障原因 显示方式 显示优先级别 PG反馈异常 每8秒闪烁4次 1 T环异常 每8秒闪烁1次 2 T内盘异常 每8秒闪烁2次 3 T外盘异常 每1秒闪烁1次 4 AUX故障代码: KFR-70LW/ A, KFR-120LW/ A故障显示和保护显示 1, 制热化霜: 面板上'制热'指示灯闪烁. (0.5s/ O. 5s) ,其余不变. 2, 有室内管温时, 室内制冷防冻结保护: 面板上'运行'灯和'制冷'显示闪烁 (0.5s/ 0.5s) 其余不变. 3, 有室内管温时, 室内制热防高温保护: 面板上'运行'灯和在'制热'显示闪烁 (0.5s/ 0.5s) 其余不变. 4, 有室内管温时, 室内制热长时间防冷风保护: 面板上'运行'灯闪烁 (0.5s/ 0.5s) 其余不变. 5, 过流保护: '运行'灯和'29'指示灯同时闪烁 (0.5s/ 0.5s) ,系统停机? 6, 低压保护: '运行'灯和'18'指示灯同时闪烁 (0.5s/ 0.5s) ,系统停机? 7, 室温传感器故障: '温度'指示灯闪烁 (0.5s/ 0.5s) ,系统停机? 8, 室内盘管传感器故障: '温度'指示灯闪烁 (0.5s/ 0.5s) ,按无内管传感器运行? 9, 室外盘管传感器故障: '温度'指示灯闪烁 (0.5s/ 0.5s) 其余不变. 10, 室外缺相或者相序保护 '定时'灯和'运行'灯同时闪烁 (0.5s/ 0.5s) 系统停机? 11, 通讯故障: '运行'灯闪烁 (0.5s/ 0.5s) ,其余指示灯灭, 系统停机? FS (Y) ,DS (Y) ,ZVY, CSY型空调故障显示和保护显示当发生故障时, 操作板LED数码屏上显示故障的相应代码. 1, 室温传感故障: 系统停机, 操作板LED数码屏上显示'E1' 2, 室内板上室外管温传感故障: 系统不停机, 操作板LED数码屏上'E2' 3, 室内管温传感故障: 系统不停机, 操作板LED数码屏上'E3', 按无室内管温传感器时方式工作. 4, 室外有板时, 通讯故障: 系统停机, 操作板LED数码屏上'E4' 5, 室外有板时, 室外压缩机保护 (过载保护) : 系统停机, 操作板LED数码屏上'E5'. (可能是低开关压保护, 过载保护或过载 继电器动作) 6, 室外有板时, 室外三相缺相保护: 系统停机, 操作板LED数码屏上'E6'. (可能是三相接反) . 7, 室外有板时, 过流保护: 系统停机, 操作板LED数码屏上'E7' 8, 室外有板时, 压缩机排气管温度传感器故障: 系统不停机, 操作板LED数码屏上'E8'. (可能是温度传感器接插不牢或室外 电脑板坏) 9, 室外有板时, 压缩机排气管温度保护: 系统停机, 操作板LED数码屏上'E9 空调试机必须注意七大事项 1, 观察外机有无障碍物, 取下内机机罩, 清理外机附近的物品. 2, 打开室内机壳观察内机过滤网有无灰尘及异味, 请定期清洗过滤网. 清洗过滤网的方法: ①, 首先切断电源; ②, 打开面板 (柜式机带有进风栅固定螺丝应先卸掉螺丝后, 打开进风栅) ; ③, 取出过滤网; ④, 清洗过滤网 (用毛刷式 吸尘器 除尘后, 再用清水洗净, 太脏有油污时, 用除污剂或中性肥皂水清洗, 用清水滤净后, 晾干装好) ; ⑤, 注意不要用40℃以上的热水清洗. 3, 插电等3-5分钟, 将遥控器设置在制冷模式, 温度设定在最低的条件下, 开机运行 (最好在中午和下午试机) . 4, 空调运行后, 将遥控器的风速开关设定在不同的档位上运行, 观察内机有无异常噪音. 5, 开机运行15分钟左右观察外机风扇是否运转正常, 外机有无异常噪音. 6, 开机运行30分钟左右观察室内机出风有无冷风感, 室外机 出水管有无冷凝水流出, 流水是否畅通. 7, 空调运转会出现的正常现象: ①, 偶有噼啪声或塑料响声: 这是由于空调制冷运转时内机面板遇到冷热膨胀所引起, 不会影响正常使用. ②, 有出气或流水声: 制冷剂在内机流动, 蒸发产生的声音. ③, 有白烟雾从内机吹出: 室内空气湿度过大, 被空调冷气冷凝所产生, 属正常现象. ④, 叶片或管路上有水珠: 室内湿度大, 设定温度低所造成二次冷凝, 尽量使内机扫风片设定水平, 保持室内机出风通畅. ⑤, 外机裸露通管, 接头有水珠滴水: 空气中水分子冷凝形成, 属正常现象. ⑥, 变频空调室外机声音时大时小: 这是由于变频空调空调压缩机运转频率改变发生现象.
春兰 空调 故障代码 春兰KFR-70td; Tds; H2d; H2ds; 50H2d; 50Vd; 72vd; 120vds柜机故障代码 E1 排气温度过高 E2 压缩机过电流 E3 相序错误 E4 系统压力过高 E5 系统压力过低 E6 防冻结保护 春兰KFR-2232GA分体故障代码 显示内容 故障原因 红灯不亮 主电源, 变压器或主控板故障 绿灯闪烁 压力继电器断开或RT2管温异常 黄灯闪烁 RT2温度传感器短路或开路 绿灯与黄灯同时闪烁 FT1或FT2断开保护 春兰 KFR-35GW / BP故障代码 E0 通讯故障 E1 室外传感器开路 E2 压缩机过载 E3 过流保护 E4 功率模块保护 E5 室外管温过高保护 E6 排气温度过高保护 E7 系统压力异常 (预留) E8 Pg电机转速异常 E9 室内管温过高 HY1系列挂机故障代码 E1 室内管温异常 E2 内风机转速异常 E3 压力过高 (实为主控板异常) 故障代码机型为: 春兰 KFR--120LW/ BP 显示代码 故障内容 E0 通信失败 E1 室外传感器开路. 短路 E2 压缩机过载 E3 过电流 E4 IPM保护 E5 室外机 管温过高 E6 排气温度过高 E7 过久压保护 E8 室内机传感器开路. 短路 闪灭 亮 室外环温温度传感器异常 春兰KFR-32GW/ BP故障代码 绿灯闪 室内环温异常 黄灯闪 室外机故障 黄绿红同时闪 FT断开路 红灯不亮 主电源, 变压器或主控板故障 绿灯闪烁 压力继电器断开或RT2管温异常 黄灯闪烁 RT2温度传感器短路或开路 绿灯与黄灯同时闪烁 FT1或FT2断开保护 黄绿红交替闪 室内外通讯故障 春兰KFR-405070100140LW/ BdS故障代码 显示内容 故障原因 E1 室内外通讯故障 (GND与CMM之间电压在6-7V左右摆动) E2 压缩机过电流 E3 电源电压异常 E4 制冷系统压力过高保护, RT5传感器异常 E5 室外环温过低保护 E6 过冷保护 (制冷状态) RT2异常 E7 RTI, RT2, RT3温度传感器开路 E8 RTI, RT2, RT3温度传感器短路 春兰FR-180260/ S风管机故障代码 显示代码 故障原因 E0 系统高压保护 E1 二次防冻结保护 故障代码机型为: 春兰KFR--120LW/ BP 显示代码 故障内容 E0 通信失败 E1 室外传感器开路. 短路 E2 压缩机过载 E3 过电流 E4 IPM保护 E5 室外机管温过高 E6 排气温度过高 E7 过久压保护 E8 室内机传感器开路. 短路 新品春兰2005故障代码V系列空调 E1 排气管温度过高 E2 压缩机过电流 E3 电源相序错误 E4 系统压力过高 E5 系统压力过低 E6 防冻结保护
大金 空调 器故障代码 大金FTY系列分体式空调器故障代码 故障代码故障原因 A6风扇系统故障, 风扇电机有问题. C4室外管温热敏电阻有故障. C9室外微风热敏电阻有故障. U4室内机与室外 控制 线接触不良或接错.U5室内机与遥控器接触不良.E5过载可压缩机超负荷运行.E3高压过高使压力继电器断开保护.H3高压控制器本身有故障.H9室外温度传感器本身有问题.J6热交换器的感温器有故障.P3电气箱内的感温器有故障 以上代码适用于FTY223C, FTY353C, FTY453C, FTY603C等机型, 该机实现自动诊断故障功能的操作步骤是: 当按动空调器选择运行方式时, 则按下'时间'键3秒钟以上, 空调器自动进入故障诊断测试状态, 再按下异常信号检测键, 如果存在故障, 故障代码将出现在液晶板的温度显示屏上 ` 大金 FVT- (125) ,(71) B系列柜式 LED-ALED-BLED-1LDE-2LED-10故障内容 `(绿色) (绿色) (红色) (红色) (红色) `室内主控制板闪亮闪亮灭灭灭室内正常, 检查 室外机 `闪亮---闪亮系统设置故 `正常----室内机主控制板故障 `灭----电源线以, 室内机故障 `室外主控制板闪亮 灭闪亮-电源相序不对 `闪亮闪亮-传感器故障 `闪亮灭-室外机保护器损坏 `该机是通过室内外电路板上各一绿二红故障灯与面板上一红灯点亮, 提示故障范围, 正常状态绿灯闪, 红灯全灭, 出现故障时能记忆保存, 排除故障后关断电源20秒以上, 否则二次送电后故障灯将一直显示. `大金SKY FREE i系列故障代码 `A0 室内机: 外部保护装置异常 A1 室内机: 电路板不良 A3 室内机: 排水水位控制系统异常 (33H) A6 室内机: 风扇马达 (M1F) 锁定 过负载 A7 室内机: 风门挡板摆动马达 (M1S) 异常 AF 室内机: 电子膨胀阀部分 (Y1F) 异常 AJ 室内机: 水位超限 `大金SKY FREE i 系列2 C4 室内机: 液管用热敏电阻 (R2T) 异常 C5 室内机: 气管用热敏电阻 (R3-1T (R3-2T) ) 异常 C9 室内机: 吸入空气用热敏电阻 (R1T) 异常 CJ 室内机: 遥控器用热敏电阻异常 `大金RY71FPVIL, RHC71FPVL, RY-125FPSYIL, RVY125PVL空调器代码 `C4-室内机热交换异常. `C9-吸入温度感应异常. `E0-保护装置动作. (风扇电机温度异常或压缩机过流) `E3-高压压力HPS异常. `E4-保护装置动作. (LPS动作或LPS异常) `F3-压缩机排气温度异常. `H3-保护装置动作. (高压压力异常) `H9-室外机传感器不良. (环温不良) `J3-吐出温度异常. (吐出传感器不良) `J6-排气温度异常. (排气温度感应系统异常) `R1-室内机控制系统异常. `R3-排水系统异常. `R7-风向调节异常. `U1-相序错误. `U2-电压过低. `U4-通信故障. (控制面板与室内机的发送信息错误) `U5-通信故障. (室内机与控制面板的发送信息错误) `UF-通信故障. (室内机与室外机通信息错误) `UR-控制面板设置不良. FTY系列分体式空调器故障代码 故障代码故障原因 A6风扇系统故障, 风扇电机有问题.C4室外管温热敏电阻有故障.C9室外微风热敏电阻有故障.U4室内机与室外控制线接触不良或接错.U5室内机与遥控器接触不良.E5过载可压缩机超负荷运行.E3高压过高使压力继电器断开保护.H3高压控制器本身有故障.H9室外温度传感器本身有问题.J6热交换器的感温器有故障.P3电气箱内的感温器有故障 以上代码适用于FTY223C, FTY353C, FTY453C, FTY603C等机型, 该机实现自动诊断故障功能的操作步骤是: 当按动空调器选择运行方式时, 则按下'时间'键3秒钟以上, 空调器自动进入故障诊断测试状态, 再按下异常信号检测键, 如果存在故障, 故障代码将出现在液晶板的温度显示屏上 `大金FVT- (125) ,(71) B系列柜式 LED-ALED-BLED-1LDE-2LED-10故障内容 `(绿色) (绿色) (红色) (红色) (红色) `室内主控制板闪亮闪亮灭灭灭室内正常, 检查室外机 `闪亮---闪亮系统设置故 `正常----室内机主控制板故障 `灭----电源线以, 室内机故障 `室外主控制板闪亮 灭闪亮-电源相序不对 `闪亮闪亮-传感器故障 `闪亮灭-室外机保护器损坏 `该机是通过室内外电路板上各一绿二红故障灯与面板上一红灯点亮, 提示故障范围, 正常状态绿灯闪, 红灯全灭, 出现故障时能记忆保存, 排除故障后关断电源20秒以上, 否则二次送电后故障灯将一直显示. `大金SKY FREE i系列故障代码 `A0 室内机: 外部保护装置异常 A1 室内机: 电路板不良 A3 室内机: 排水水位控制系统异常 (33H) A6 室内机: 风扇马达 (M1F) 锁定 过负载 A7 室内机: 风门挡板摆动马达 (M1S) 异常 AF 室内机: 电子膨胀阀部分 (Y1F) 异常 AJ 室内机: 水位超限 `大金SKY FREE i 系列2 C4 室内机: 液管用热敏电阻 (R2T) 异常 C5 室内机: 气管用热敏电阻 (R3-1T (R3-2T) ) 异常 C9 室内机: 吸入空气用热敏电阻 (R1T) 异常 CJ 室内机: 遥控器用热敏电阻异常 `大金RY71FPVIL, RHC71FPVL, RY-125FPSYIL, RVY125PVL空调器代码 `C4-室内机热交换异常. `C9-吸入温度感应异常. `E0-保护装置动作. (风扇电机温度异常或压缩机过流) `E3-高压压力HPS异常. `E4-保护装置动作. (LPS动作或LPS异常) `F3-压缩机排气温度异常. `H3-保护装置动作. (高压压力异常) `H9-室外机传感器不良. (环温不良) `J3-吐出温度异常. (吐出传感器不良) `J6-排气温度异常. (排气温度感应系统异常) `R1-室内机控制系统异常. `R3-排水系统异常. `R7-风向调节异常. `U1-相序错误. `U2-电压过低. `U4-通信故障. (控制面板与室内机的发送信息错误) `U5-通信故障. (室内机与控制面板的发送信息错误) `UF-通信故障. (室内机与室外机通信息错误) `UR-控制面板设置不良. 大金家用变频空调系列 内机型号FTX45HV1LC, FTX45HAV1LC, FTX45GV1LC, FTX52GAV1LC. 外机型号RX45HV1LC, RX45HAV1LC, RX45GV1LC, RX52GAV1LC. 故障代码及内容: 00 正常 , U0 冷媒不足 , U2 低电压检出 , U4内外机传送异常 . R1 P板不良 , R5 变压器保护防结冰 , R6 内电机异常 , C4 内温传感异常 . C5 内管温异常 , C9 室温传感异常 , E5 OL动作 , E6 压机启动不良 . E7 外风机异常 , H8 CT异常 , H9 外温传感异常 , J3 高压热敏异常 . J4 系统异常 , J5 外低压热敏异常 , J6 外热交换传感异常 . J9 外气体管道热敏异常 , L4 外风机温度高 , L5 输出过电流 , P3 电箱温度传感异常 , P4 外管温异常
|